Commissioning
System Manual 2CKA001473B5074
│52
Use the following points for commissioning the "Electronic cylindrical lock":
1. Ensure that there is a radio connection between the reading head and the "Smart Access
Point Pro". The radio connection can be implemented in different ways.
■
The "Electronic cylindrical lock" is already mounted:
– The communication is carried out directly with the "Smart Access Point Pro" or via
the already available installation of interconnected auxiliary devices ("RF Repeater" /
"RF/IP Gateway".
– If communication is not possible, the reading head of the "Electronic cylindrical lock"
must be dismantled and put near the "Smart Access Point Pro". For additional
information: see chapter 3.2.2 “Adding larger projects / devices in advance“ on page
55.
■
The "Electronic cylindrical lock" is not yet mounted:
– The "Electronic cylindrical lock" together with the required ancillary devices is
brought into the radio range of the "Smart Access Point Pro". For additional
information: see chapter 3.2.2 “Adding larger projects / devices in advance“ on page
55.
click!
1
2
Fig. 41: Pulling the head housing off
2. Unlock the head housing of the reading head with the mounting tool [1] and pull it off [2].
1
Fig. 42: Serial number
3. Note down the serial number [1].
– The serial number is necessary for logging into the management software of the "Smart
Access Point Pro".
- Also scanning the QR code and logging in with the ABB-Welcome
®
App is possible.