Chapter 6 – Preventive Maintenance
6-4
ACS 600 MultiDrive
Method 2 A
Capacitor reforming is realised by connecting a rectifier and a resistor
circuit to the converter DC link. The reforming circuit and component
values for different voltages are given below. See Figure 6-1 for the
reforming time.
WARNING!
The converter supply must be disconnected while the
reforming circuit is connected.
Supply Voltage
Recommended Components
A
R
C
380 V <
U
1
< 415 V
SKD 82/16
220 Ohm / 700 W
22 nF / 2000 V
380 V <
U
1
< 500 V
SKD 82/16
470 Ohm / 1200 W
22 nF / 2000 V
525 V <
U
1
< 690 V
SKD 82/16
680 Ohm / 1700 W
22 nF / 2000 V
L–
L+
R
A
C
U
1
1.35
×
U
1
Converter
or phase module
W2 (W1)
U2 (U1)
V2 (V1)
Disconnect