Presentation / operation
ABB Control - AC 31
Page 2-9
1SBC 260400 R1001-b
06.99
3.4.3. Inserting variables
Select the
"
Insert variable"
icon (Figure 2-10) in the program editor window. Then place
the cursor to the left of the function block, making sure that enough space is left so that the
input variable does not overlap the function block, and click on the mouse.
Select the
"I62.00 - IN1 - Switch"
variable in the variable list
Validate with
"OK"
. The variable appears with its name.
Comment: If the
"Cannot overlap graphic symbols"
message appears instead of the
variable then restart the manipulation leaving enough space to the left of the block for the
variable insertion
Use the same procedure to insert the internal bit to the left of the function block and below
of the input variable and select the
"M00.00 - TEST"
internal bit.
Use the same procedure to insert the output variable to the right of the function block and
select the
"O62.00 - OUT1 - Lamp"
variable.
3.4.4. Links between the variables and the function block:
Select the
"Draw connection line"
icon in the program editor window (Figure 2-11) and
draw a line, without releasing the mouse button, between the
"IN1"
variable and the block.
The link between the
"TEST"
internal bit and the block is drawn in the same manner.
The link between the
"OUT1"
variable and the block is drawn in the same manner.
The programming phase is finished once the links are established. You may now save,
compile and send the program to the PLC.
3.5. Saving
Click on the
"Save"
icon in the program editor window to save your program.
3.6. Compilation
Compiling corresponds to a program verification and translation into a PLC understandable
language.
Click the
"Verify program"
icon in the program editor window
.
Click the
"Verify"
button
,
wait for the message
"0 error detected"
(Figure 2-12) then click on
the
"Build"
button.
Once the
"Project ready for download"
message has appeared
(
Figure 2-13), click on
"Exit"
to exit and return to the DEMO:MAIN program editor window.
Содержание AC 31
Страница 1: ...Technical Manual Advant Controller 31 40 50 Series 1SBC 260400 R 1001 b ...
Страница 7: ......
Страница 28: ...AC 31 technical documentation ABB Control AC 31 Page 2 1 1SBC 260400 R1001 b 06 99 Chapter 2 Getting started ...
Страница 43: ......
Страница 45: ...Technical specifications Page 3 2 ABB Control AC 31 1SBC 260400 R1001 b 06 99 ...
Страница 83: ......
Страница 84: ...AC 31 technical documentation ABB Control AC 31 Page 4 1 1SBC 260400 R1001 b 06 99 Chapter 4 Installation ...
Страница 85: ...Installation Page 4 2 ABB Control AC 31 1SBC 260400 R1001 b 06 99 ...
Страница 109: ......
Страница 110: ...AC 31 technical documentation ABB Control AC 31 Page 5 1 1SBC 260400 R1001 b 06 99 Chapter 5 Programming ...
Страница 130: ...Programming ABB Control AC 31 Page 5 21 1SBC 260400 R1001 b 06 99 ...
Страница 141: ...Programming Page 5 32 ABB Control AC 31 1SBC 260400 R1001 b 06 99 Figure 5 10 Duplicating inputs of a function block ...
Страница 154: ...AC 31 technical documentation ABB Control AC 31 Page 6 1 1SBC 260400 R1001 b 06 99 Chapter 6 Program Optimization ...
Страница 172: ...AC 31 technical documentation ABB Control AC 31 Page 7 1 1SBC 260400 R1001 b 06 99 Chapter 7 Communication ...
Страница 182: ...Communication ABB Control AC 31 Page 7 11 1SBC 260400 R1001 b 06 99 ...
Страница 189: ......
Страница 190: ...AC 31 technical documentation ABB Control AC 31 Page 8 1 1SBC 260400 R1001 b 06 99 Chapter 8 Diagnosis ...
Страница 191: ...Diagnosis Page 8 2 ABB Control AC 31 1SBC 260400 R1001 b 06 99 Figure 8 1 Error detection LEDs ...
Страница 195: ...Diagnosis Page 8 6 ABB Control AC 31 1SBC 260400 R1001 b 06 99 Figure 8 2 AC31GRAF status window ...
Страница 203: ......
Страница 204: ...AC 31 technical documentation ABB Control AC 31 Annexes Page 1 1SBC 260400 R1001 b 06 99 Annexes ...
Страница 217: ......
Страница 218: ...AC 31 technical documentation ABB Control AC 31 Index Page 1 1SBC 260400 R1001 b 06 99 Index ...