![ABB ABB-free@home flex Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/abb/abb-freeathome-flex/abb-freeathome-flex_product-manual_3343970042.webp)
Commissioning
Product manual 2CKA001473B5285
│
42
Pos. Description
[1]
Device name
The text field can be used to assign your own designation for the device.
[2]
Position
By tapping the drop-down menu, you can assign the device a position in the building
structure you have defined (e.g. assignment to a room on a specific floor).
[3]
Incoming pairings
You can use this function to connect the actuator with a function of an extension unit
and a rocker.
Tap the plus symbol in front of the function, extension or rocker to open a list. In this list,
the desired pairing can be selected by tapping on it. A successful pairing is indicated
by a check mark.
■
Tap the trash can icon to cancel the pairing.
[4]
Timer programs
Listing and configuration of timer programs.
■
Tapping on a timer program opens the configuration. By tapping on the plus symbol,
you can configure a new time program.
[5]
Calibration
You can calibrate the blind via the Calibration menu item.
[6]
Authorizations
The "Authorizations" menu item is used to specify whether an installer authorization is
required for the configuration.
[6]
Function
The function of the actuator is defined via the "Function" menu item.
■
Blind
actuator
■
Roller blind actuator
■
Roof window actuator
■
Awning actuator
[7]
Symbol
The menu item Symbol is used to define a symbol with which the actuator is displayed.
[8]
Parameters
Total travel time upwards [s]
Setting the movement time up/down in
seconds via the -/+ buttons
Total travel time down [s]
Setting the movement time up/down in
seconds via the -/+ buttons
Total slat travel time [ms]
Setting the time in milliseconds via the
−
/+
buttons, which the slats require for a
complete change in direction of their
angle.
The time for a single step is fixed at 200
ms and cannot be changed.
Behaviour during faults
Display of information only. No settings
possible.
Motor dead time [ms]
Setting the motor pause time in
milliseconds via the -/+ buttons
■
This value is required for the slat
adjustment.
■
Check the operating instructions of the
blind motor to determine the correct
motor dead time (period between
switching the actuator and starting the
motor).