Commissioning
Product manual 2CKA001473B5285
│
33
Pos. Description
[1]
Links
Under "Links" you can create or delete links. You can also see for which devices a link
was created. A difference is made between links of channels and scenes.
■
A list opens when tapping the plus icon in front of the channel or scene. Create the
desired link in the list by tapping on the desired device. A successfu link is indicated
with a tick.
■
The link can be deleted by tapping on the dustbin icon.
[2]
Function
The function is selected automatically in dependence of the selected link. It can be
changed if necessary.
■
Control element
For the control of switching processes
■
Dimming operation
For the control of dimming processes
■
Switching operation with switch-off delay
A specified switch-off delay starts after the successful switching process. This, for
example, specifies how long the light remains switched on after the actuator has
deactivated the load.
■
Sensor force-position On/Off
The actuator is put into the "Activated" or "Deactivated" state and locked against
any further operation. After cancelling the forced control, the actuator returns to its
original state.
■
Block actuator
The actuator is put into the "Deactivated" state and locked against any further
operation. After cancelling the forced control, the actuator returns to its original
state.