ABB-free@home
®
05 Types of Devices
System Manual
│
39
Parameter settings Sensor/dimming actuator, 1/1gang
Actuator settings
[1]
Changing the name
[2]
Deleting the channel via 'X'
[3]
Switching of the actuator via the button; dimming the actuator via
buttons -/+
[4]
Setting of the load connected to the actuator. Selection between:
- Automatic load detection
- Inductive load
- Dimmable LED/KLL
- Incandescent lamp
[5]
Setting the minimum brightness in % via buttons -/+
[6]
Setting the maximum switch-on brightness during the day in % via
buttons -/+
[7]
Setting the maximum switch-on brightness during the night in % via
buttons -/+
[8]
Setting the switch-off delay in seconds. Buttons -/+ can be used to
specify, for example, how long the light remains on after the actuator
has deactivated the load.
Sensor settings
[1]
Changing the name
[2]
Deleting the channel via 'X'
[3]
Selecting the rocker in the list view
Rocker settings
[1]
Changing the name
[2]
Switching the sensor via the button
[3]
Setting the LED night/day switch-on brightness in % via the -/+ buttons:
This parameter can be used to specify how strong the LED lights percent-
age-wise at night/day.
Attention! The parameter only functions when a time profile with the appli-
cation "LED day/night switchover" is available. The device (channel) must
be linked with this application!
Application symbol:
[4]
Selecting the LED operating mode:
Light for orientation: LED lights permanent.
Status display: LED lights when actuated.
For pre-programmed devices the following parameter is available immediately. For all other devices it only becomes available
after being linked with an actuator. The setting in the list view is then made via the linking function of the Web-based user
interface of the System Access Point.
[5]
Selecting the function: Control element; dimming sensor; stairwell light
sensor; sensor force-position On/Off; blind sensor; blind force-position
Parameter settings Sensor/dimming actuator, 2/1gang
Actuator settings:
As for 1/1gang.
Sensor settings:
As for 1/1gang; however, 2 rockers (left and right rocker) are displayed in the list view.
Rocker settings:
As for 1/1gang; however, the settings can be made for 2 rockers (left and right rocker).
Содержание ABB-free home
Страница 1: ...ABB free home System Manual ...
Страница 2: ...2 System Manual ...
Страница 19: ...ABB free home 04 Commissioning System Manual 19 Fig 13 Basic settings ...
Страница 33: ...ABB free home 04 Commissioning System Manual 33 Fig 28 Panel ...
Страница 75: ...ABB free home 08 FAQ und Tipps System Manual 75 ...