Operation Manual / 4 Product description / A130-H.. - A140-H..
9
Taking out of operation at short notice
Page 101 / 115
© Copyright 2015 ABB. All rights reserved.
HZTL4030_EN
Revision C
September 2015
9
Taking out of operation at short notice
9.1
Possible emergency repairs
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can cause severe personal
injury or fatal accidents can result.
Cordon off danger area.
Sound an alarm and depending on the situation, stop the engine.
Seal oil leaks.
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves against thermal risks.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-compliance
with the directives for blanking the turbocharger off the engine.
Follow the directives of the enginebuilder.
If the engine has to be operated again as quickly as possible following a turbocharger defect,
then the following options are available for emergency repairs:
Installing a replacement turbocharger [➙
Installing a replacement cartridge group [➙
If a replacement turbocharger or cartridge group is not available:
and contact an ABB Turbocharging Service Station.
Observe the following sections in connection with the emergency repairs mentioned.
Содержание A140-H55
Страница 4: ......
Страница 12: ......
Страница 30: ......
Страница 32: ......
Страница 36: ......
Страница 42: ......
Страница 60: ......
Страница 76: ......
Страница 96: ......
Страница 104: ......
Страница 132: ......
Страница 140: ......
Страница 144: ......
Страница 146: ......
Страница 148: ......