Operation Manual / 4 Product description / A130-H.. - A140-H..
6
Periodic maintenance work
Page 48 / 115
© Copyright 2015 ABB. All rights reserved.
HZTL4030_EN
Revision C
September 2015
72000 Compressor casing
27000 External water pressure vessel
27005 Sealing plug
01
Water pipe to filter silencer or air suction branch
02
Pressurized air inlet pipe
03
Valve activator
Pressurized air from the compressor casing (72000) of the turbocharger passes through the
pipe (02) to the water pressure vessel (27000). As soon as the valve activator (03) is
activated, water is pressed into the pipe (01) and routed to the filter silencer or air suction
branch.
The water does not act as a solvent. The coating is removed by the mechanical action of the
impacting droplets.
Содержание A140-H55
Страница 4: ......
Страница 12: ......
Страница 30: ......
Страница 32: ......
Страница 36: ......
Страница 42: ......
Страница 60: ......
Страница 76: ......
Страница 96: ......
Страница 104: ......
Страница 132: ......
Страница 140: ......
Страница 144: ......
Страница 146: ......
Страница 148: ......