10
10
/6
1SBC104001M1701
1SBC388162F0302
GB
F
R.. (A)
"V" mm
Type
Order code /
N° d'identification
kg
R..85
(1)
180
VM 22
(2)
FPL 710 1403 R0002
0.120
R..85
(1)
220
VM 21/24 FPL 710 1403 R0001
0.140
R..170
(1)
220
R..260
(1)
260
VM 26
FPL 760 1404 R0001
0.250
R..420
(1)
320
VM 14
FPL 800 1401 R0001
0.360
R..550
(1)
400
VM 15
FPL 830 1401 R0001
0.500
R..800, 1000 520
VM 16
FPL 860 1401 R0001
0.600
R..1250
640
VM 17/18 FPL 880 1401 R0001
0.700
R..1500
640
R..2000
680
VM 19
FPL 900 1401 R0001
0.800
VM..
GB
F
V
R..63 ... R..550
R..800 ... R..2000
V
Accessoires
Verrouillage mécanique
(1) Valable également pour U
e
< 440 V d.c.
(2) Montage sur types
IOR
,
IORE
,
LOR
,
LORE
avec 2 blocs de contacts auxiliaires
CA-12..
maxi.
Note :
pour verrouiller des contacteurs de calibres différents, des dispositifs de verrouillage
adaptés et des rallonges d'arbres peuvent être fournis.
>>
Essais de fonctionnement ..............................................................................pages 8/16, 8/46
Dispositif de verrouillage mécanique VM..
L'adjonction d'un dispositif de verrouillage mécanique entre 2 contacteurs de
même calibre, ou 2 coupleurs, montés superposés, est sans influence sur les
cotes de fixation et d'encombrement de chaque contacteur.
Le tableau ci-dessous indique les entraxes de fixation "V" entre :
– 2 contacteurs
IOR
,
IORR
,
IORE
de même calibre (U
e
< 500 V, 50 et 60 Hz)
– 2 coupleurs
LOR
,
LORR
,
LORE
de même calibre (U
e
< 1000 V, 50 et 60 Hz
ou 1000 V d.c.).
Pour contacteurs
IORC
et coupleurs
LORC
ou pour d'autres tensions U
e
: nous
consulter.
Les dispositifs de verrouillage mécanique sont toujours livrés séparément. Les
instructions de montage et de réglage de cet accessoire sont fournies avec le
matériel.
Références de commande
Verrouillages pour inverseurs (2 contacteurs de même calibre). Pour autres versions nous
consulter.
Accessories
Mechanical Interlocking
(1) Valid also for U
e
< 440 V d.c.
(2) Mounting on
IOR
,
IORE
,
LOR
,
LORE
types with max. 2
CA-12..
auxiliary contacts blocks.
Note:
for interlocking between contactors of different ratings, specific interlocking devices
and shaft extensions can be supplied.
VM.. Mechanical Interlocking Device
The mounting of a mechanical interlocking device between 2 contactors of a same
rating, or 2 couplers, vertically mounted, does not affect their fixing centres or
their overall dimensions.
The table below gives the vertical fixing centres "V" between:
– 2
IOR
,
IORR
,
IORE
contactors of a same rating (U
e
< 500 V, 50 and 60 Hz)
– 2
LOR
,
LORR
,
LORE
couplers of a same rating (U
e
< 1000 V, 50 and 60 Hz
or 1000 V d.c.).
For
IORC
contactors and
LORC
couplers or other voltages U
e
:
please consult us.
The mechanical interlock units are always supplied separately.
The instructions for mounting and adjustment of this accessory are supplied
with the product.
Ordering Details
Interlocking devices for reversing contactors (2 contactors of a same rating). For other ver-
sions please consult us.
>> Operating Tests ...............................................................................................pages 8/16, 8/46
Содержание 266M R Series
Страница 1: ...GB F Instruction Handbook R Series Contactors Notice d instructions Contacteurs Série R ...
Страница 2: ......
Страница 48: ...7 2 1SBC104001M1701 7 GB F Notes Notes ...
Страница 110: ...8 62 1SBC104001M1701 8 GB F ...
Страница 124: ...10 10 8 1SBC104001M1701 GB F Notes Notes ...
Страница 128: ...11 4 1SBC104001M1701 11 GB F Notes Notes ...
Страница 137: ...12 9 1SBC104001M1701 12 GB F Notes Notes ...