4.5 Function tests
4.5.1 Function test of emergency stop
Overview
Perform this test on the FlexPendant emergency stop button.
Performing the function test
Note
Action
If any damage is found on the emergency
stop button, it must be replaced.
Make a visual inspection of the emergency
stop button to make sure it is not physically
damaged.
1
Pull and rotate the emergency stop button
clockwise to verify that it is not pressed in.
2
Start the robot system.
3
The test is passed if the event message
10013 Emergency stop state
appears in
the event log.
Note
For collaborative robots, the event mes-
sage
90518 Safety controller Emergency
stop triggered
appears by default. The
message
10013 Emergency stop state
is
also available in the event log.
Press the emergency stop button.
Note
If the event message
20223 Emergency
stop conflict
appears in the event log, or
the event message
10013 Emergency stop
state
(and
90518 Safety controller Emer-
gency stop triggered
for collaborative ro-
bots) does not appear, then the test has
failed and the root cause of the failure must
be found.
4
Release the emergency stop button to reset
the emergency stop state.
5
Product manual - OmniCore C90XT
171
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
4 Maintenance
4.5.1 Function test of emergency stop
Содержание OmniCore C90XT
Страница 1: ...ROBOTICS Product manual OmniCore C90XT ...
Страница 2: ...Trace back information Workspace 21B version a6 Checked in 2021 05 31 Skribenta version 5 4 005 ...
Страница 36: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 360: ...This page is intentionally left blank ...
Страница 420: ...This page is intentionally left blank ...
Страница 428: ...This page is intentionally left blank ...
Страница 452: ...This page is intentionally left blank ...
Страница 456: ......
Страница 457: ......