2 Installation
2.1 Connecting the BDI3000 to Target
The cable to the target system is a 16 pin flat ribbon cable. In case where the target system has an
appropriate connector, the cable can be directly connected. The pin assignment is in accordance with
the COP connector specification.
In order to ensure reliable operation of the BDI (EMC, runtimes, etc.) the target cable length must not
exceed 20 cm (8").
For BDI TARGET B connector signals see table on next page.
Note:
For critical designs (long traces on the target board) there is a shorter target cable available (p/n
90020-S).This may improve JTAG communication reliability. But best is to keep the JTAG traces on
the board as short as possible.
Warning:
Before you can use the BDI3000 with an other target processor type (e.g. PPC <--> ARM), a new
setup has to be done (see chapter 2.5). During this process the target cable must be disconnected
from the target system.
To avoid conflicts between data lines, the BDI3000 must be disconnected from the target sys-
tem while programming a new firmware for an other target CPU.
!
COP/JTAG Connector
BDI
3000
Target System
1
15
16
2
1 - TDO
2 - NC (QACK)
3 - TDI
4 - TRST
5 - NC (QREQ)
6 - Vcc Target
7 - TCK
8 - CHKSTP_IN
9 - TMS
10 - NC
11 - SRESET
12 - GROUND
13 - HRESET
14 - NC (key)
15 - CHKSTP_OUT
16 - GROUND
The green LED «TRGT» marked light up when target is powered up
TARGET A
TARGET B
15
1
16
2
BDI
TRGT
MODE
P4080
!