bdi
GDB
for BDI3000 (QorIQ P3/P4/P5)
User Manual
16
© Copyright 1997-2012 by ABATRON AG Switzerland
V 1.03
2.5.3 Configuration via Telnet / TFTP
The firmware update and the initial configuration of the BDI3000 can also be done interactively via a
Telnet connection and a running TFTP server on the host with the firmware file. In cases where it is
not possible to connect to the default IP, the initial setup has to be done via a serial connection.
To avoid data line conflicts, the BDI3000 must be disconnected from the target system while
programming the firmware for an other target CPU family.
Following the steps to bring-up a new BDI3000 or updating the firmware.
Connect to the BDI Loader via Telnet.
If a firmware is already running enter "boot loader" and reconnect via Telnet.
$ telnet 192.168.53.72
or
$ telnet <your BDI IP address>
Update the network parameters so it matches your needs:
LDR>network
BDI MAC : 00-0c-01-30-00-01
BDI IP : 192.168.53.72
BDI Subnet : 255.255.255.0
BDI Gateway : 255.255.255.255
Config IP : 255.255.255.255
Config File :
LDR>netip 151.120.25.102
LDR>nethost 151.120.25.112
LDR>netfile /bdi3000/mytarget.cfg
LDR>network
BDI MAC : 00-0c-01-30-00-01
BDI IP : 151.120.25.102
BDI Subnet : 255.255.255.0
BDI Gateway : 255.255.255.255
Config IP : 151.120.25.112
Config File : /bdi3000/mytarget.cfg
LDR>network save
saving network configuration ... passed
BDI MAC : 00-0c-01-30-00-01
BDI IP : 151.120.25.102
BDI Subnet : 255.255.255.0
BDI Gateway : 255.255.255.255
Config IP : 151.120.25.112
Config File : /bdi3000/mytarget.cfg
In case the subnet has changed, reboot before trying to load the firmware
LDR>boot loader
!