Program Interface Library
AR_GET_LABEL_FILTER
CEI-100/CEI-200/CEI-
x20 User’s Manual
86
AR_GET_LABEL_FILTER
CEI_INT16 ar_get_label_filter (CEI_INT16 board, CEI_UINT16 label);
This function may be called to determine if a specified label has been
filtered out, or if normal reception has been enabled. Label filtering is
enabled by the functions AR_LABEL_FILTER, or for the CEI-
520/520A/620/820/820TX enhanced API, the function AR_PUTFILTER.
The value of the label filter, for all channels, is returned by this function.
This value consists of a bit field; the least significant bit is set if the label
is filtered out on channel 0, the next bit is set if the label is filtered out on
channel 1, etc.
board
(input) the board of interest.
label
(input) the label of interest.
Syntax
Description
Return Value
Arguments