Program Interface Library
AR_GET_CONFIG
CEI-100/CEI-200/CEI-
x20 User’s Manual
81
AR_OFF
Transmitter is configured for normal
transmission
If the requested CEI-x20 item is ARU_DISCRETE_INPUTS, this
function returns the current state of the 4/8/16 discrete inputs, as the
lower 4/8/16 bits of the value. These discretes are active high sense.
If the requested CEI-x20 item is ARU_DISCRETE_OUTPUTS, this
function returns the current state of the 4/8/16 discrete outputs, as the
lower 4/8/16 bits of the value. The discrete output values are set using
the AR_SET_CONFIG routine.
If the requested CEI-x20 item is ARU_TX_CHnn_HB_INJ, where nn
is the transmitter channel (01 - 32), this function returns:
AR_ON
Extra transmit data bit is enabled
AR_OFF
Extra transmit data bit is disabled (normal
operation)
If the requested CEI-x20 item is ARU_TX_CHnn_LB_INJ, where nn
is the transmitter channel (01 - 32), this function returns:
AR_ON
Transmit one too few data bits is enabled
AR_OFF
Transmit one too few data bits disabled
(normal operation)
If the requested CEI-x20 item is ARU_TX_CHnn_GAP_INJ, where
nn is the transmitter channel (01 – 32), this function returns:
AR_ON
Transmit short gap is enabled
AR_OFF
Transmit short gap disabled (normal
operation)
If the requested CEI-x20 item is ARU_RX_CHnn_WAIT_PENDING,
where nn is the receiver channel (01 – 32), this function returns:
AR_TRUE
There is currently a pending ‘await data’
mode wait operation on this receiver
AR_FALSE
There is currently no pending ‘await data’
mode wait operation on this receiver
If the requested CEI-x20 item is ARU_RX_CHnn_AWAIT_DATA,
where nn is the receiver channel (01 – 32), this function returns:
AR_ON
Receiver ‘await data’ mode is enabled on this
receiver
AR_OFF
Receiver ‘await data’ mode is not enabled on
this receiver (default)
The remaining parameters are supported by the CEI-x20 only, and only if
the PARAMETRIC option was purchased. If these parameters are used
with a CEI-100/200 board, they return an error and perform no operation.
If used with a CEI-x20 that doesn’t support the function, no operation is
performed.
If the requested CEI-220/520/520A/620/820 item requests a DAC
value, this function returns the raw DAC setting. This setting is
converted to a voltage via the following equation:
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com