Solares
TM
Smart Spa Parts Manual
CD0039
18
Rev:1121
Replacement Instructions
1.
Disconnect actuator from electrical box by twisting the end of the connector counterclockwise
and pulling away from the box.
2.
Remove nuts from top and bottom shoulder bolt.
3.
Use a couple of stable supports to support the back of the tub shell.
4.
If the location of the supports is not precise then you can have a couple of people lift on the
back of the frame a bit to make it easier to remove the shoulder bolts.
5.
Remove actuator from assembly and set to the side.
6.
Install the new actuator as shown using the shoulder bolts.
7.
Black washers/ spacers can be cut out to allow them to be installed after actuator is assembled
to make it easier to get them between the brackets and the actuator. In this case the opening
should face down as to prevent the washers from falling off shoulder bolt.
8.
Reconnect actuator to electrical box by pushing it in the connector it was unplugged from. You’ll
need to rotate the end until y
ou feel the connector pop in at which point you’ll turn the nut
counterclockwise to secure the connector. If connected properly you shouldn’t be able to
simply
pull the cord off of the box.
Remedy
TM
Item
Part #
Description
Item
Part #
Description
1
200460
Remedy Box Assembly
6
401046
UB Bulb Retainer Plug
2
350229
#10 Flat Washer; SS
7
350707
O-Ring; 0.75 ID x 1.13 OD
3
350766
10-24 x 5/8 Hex Screw
8
200427
Solar Cell Assembly
4
330282
Hi-Output UV Lamp
9
N/A
Quartz Tube Assembly
5
401045
UV Bulb Compression Nut
Kit
500157
Quartz Tube Replacement Kit
–
includes items 7 and 9.