42
ControlLogix® Controller and Memory Board
Publication
1756-IN101J-EN-P - November 2004
The following specifications apply to all ControlLogix controllers:
Description:
Value:
Operating Temperature
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
•
0° … 60° C (32 … 140° F)
Storage Temperature
IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold),
IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat),
IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal Shock):
•
-40° … 85° C (-40 … 185° F)
Relative Humidity
IEC 60068-2-30 (Test Db, Un-packaged Non-operating
Damp Heat):
•
5% … 95% noncondensing
Vibration
IEC60068-2-6 (Test Fc, Operating):
•
2g @ 10-500Hz
Operating Shock
IEC60068-2-27 (Test Ea, Unpackaged Shock):
•
30g
Non-Operating Shock
IEC60068-2-27 (Test Ea, Unpackaged Shock):
•
50g
Emissions
CISPR 11:
•
Group 1, Class A
ESD Immunity
IEC 61000-4-2:
•
6kV contact discharges
•
8kV air discharges
Radiated RF Immunity
IEC 61000-4-3:
•
10V/m with 1kHz sine-wave 80%AM from 30MHz … 2000MHz
•
10V/m with 200Hz 50% Pulse 100%AM at 900Mhz
•
10V/m with 200Hz 50% Pulse 100%AM at 1890Mhz
EFT/B immunity
IEC 61000-4-4:
•
±4kV at 5kHz on power ports
•
±4kV at 5kHz on communications ports
Surge Transient Immunity
IEC 61000-4-5:
•
±1kV line-line(DM) and ±2kV line-earth(CM) on AC power ports
•
±2kV line-earth(CM) on communications ports
Conducted RF Immunity
IEC 61000-4-6:
•
10Vrms with 1kHz sine-wave 80%AM from 150kHz … 80MHz
Содержание 1756-ENBT ControlLogix
Страница 38: ...18 ControlLogix DC 10 31 2V Input Module Publication 1756 IN031D EN P February 2003 Notes ...
Страница 39: ...ControlLogix DC 10 31 2V Input Module 19 Publication 1756 IN031D EN P February 2003 Notes ...
Страница 63: ...ControlLogix Voltage Current Input Module 23 Publication 1756 IN039D EN P February 2003 Notes ...
Страница 151: ...ControlLogix Voltage Current Output Module 19 Publication 1756 5 42 September 1999 ...