30
Switch off the c-max U1.
Press the release button and
pull battery pack off by the
handle.
Connect the charger.
»
Keep the plug-in contacts
clean!
LED green = battery full
LED is red = battery is being
charged
i
Note by the manufacturer:
The charger automatically changes over to trickle charge mode once the battery pack is fully
charged. To compensate for the self-discharge of the battery, the purpose of the trickle charge
mode is to keep the batteries in a fully charged state. The LED is lit green during the trickle charge
mode.
Pull splash guard off .
i
NOTE - Protect the charger and voltage converter against oils, greases, aggressive cleaning
agents, thinning agents or damage.
i
NOTE - Observe the user manual for the charger/voltage converter.
i
NOTE - Deep discharge results in loss of capacity and a reduced service life.
i
NOTE - Before sending the batteries (repair, disposal, etc.) pack the battery pack securely. No
special cardboard packaging is needed.
i
NOTE - Do not charge the battery near heat-sensitive or fl ammable materials.
Recommendation: Remove the battery from the charger for long-term storage (or non-use). Carry out regu-
lar trickle charges at intervals of 1 month, then remove the battery from the charger again.
New batteries only reach their full capacity after several charging cycles. The batteries are mainte-
nance free and rechargeable.