Partial Reset
The Partial reset provides a way to contact the TA7104i in a known and static state while
keeping most of the configuration unchanged.
Following a partial reset, the TA7104i management interface is set to the
Rescue
interface. The
default address for this interface is 192.168.0.1/24 and has its corresponding link-local IPv6
available and printed on the sticker under the TA7104i. Any existing network interface that
conflicts with the Rescue interface address is disabled.
You can contact the TA7104i at this address to access its configuration parameters. It is not
advised to access the unit on a regular basis through the
Rescue
network interface. You should
reconfigure the unit’s network interfaces as soon as possible in order to access it through
another interface. See
After a Partial Reset
for more details.
In a partial reset, the following services and parameters are also affected:
1. AAA service: User(s) from profile are restored with their factory password.
2. SNMP service: Resets the
enableSnmpV1
,
enableSnmpV2
,
enableSnmpV3
and
snmpPort
values to their default values.
3. WEB service: Resets the
serverPort
to its default value.
To trigger the Partial Reset:
1. Insert a small, unbent paper clip into the
RESET/DEFAULT
hole located at the rear of the
TA7104i. While pressing the
RESET/DEFAULT
button, restart the unit. Do not depress
before all the LEDs start blinking (between 7-11 seconds).
2. Release the paper clip.
After a Partial Reset
Following a partial reset, you should:
1. Create or activate network interfaces as described in the
Software Configuration Guide
,
Chapter
Interface Parameters
, Section
Interfaces Configuration
. Do not disable the
Rescue
interface!
2. Change the TA7104i system management network interface to something other than
Rescue as described in the
Software Configuration Guide
, Chapter
Miscellaneous –
Management Interface
, Section
Management Interface Configuration
. Note that you must be
able to contact the interface you select in order to continue with the following steps.
3. Contact the TA7104i through the new system management network interface.
4. Disable the
Rescue
network interface as described in the
Software Configuration Guide
,
Chapter
Interface Parameters
, Section
Interfaces Configuration
.
Factory Reset
The Factory reset reverts the TA7104i back to its default factory settings. It deletes the
persistent MIB values of the unit, including: