TA7104i Hardware Installation
© 2014 Aastra Sweden | 154_1531 ANF 901| A | 2014-05-15
25
At Run-Time
The
RESET/DEFAULT
button can be used at run-time – you can press the button while the
TA7104i
is running without powering the unit off. Table 7 describes the actions you can perform in this
case.
Table 7:
RESET/DEFAULT Button Interaction
RESET/ DEFAULT
Button Pressed for:
Action
Comments
LEDs Pattern
2 to 6 seconds
Restarts the
TA7104i
No changes are made to
the TA7104i settings.
Power
LED:
•
blinking, 1Hz,
50% duty
All other LEDs:
•
OFF
7 to 11 seconds
Sets the TA7104i
in Partial
Reset Mode
Sets some of the TA7012i
configuration to pre-
determined values.
All LEDs
•
blinking, 1Hz,
50% duty
12 to 16 seconds
Restarts the
TA7104i in
Factory Reset
Deletes the persistent
configuration, creates a
new configuration file with
the default factory values,
and then restarts the unit.
All LEDs
•
steady ON
17 seconds and
more
No action is
taken
The RESET/DEFAULT
Button
Pressed event is ignored
N/A
At Start-Time
You can use the
RESET/DEFAULT
button at start-time – you power the unit off, and then
depress the button until the LEDs stop blinking and remain ON. This applies the “Factory Reset”
procedure (see
Factory Reset
). This feature reverts the TA7104i back to its default factory
settings.