Storage 

If  installation  will  not  occur  immediately 
following delivery, store equipment in a dry 
protected  area  away  from  construction 
traffic  and  in  the  proper  orientation  as 
marked  on  the  packaging  with  all  internal 
packaging in place. Secure all loose-shipped 
items. 
 

Direct Expansion (DX) Systems 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
All water-cooled condenser DX systems are 
factory assembled, leak tested, charged with 
R-410A refrigerant, and run tested. 
 
All  DX  systems  include  evaporator  coils, 
liquid  line  filter  dryers,  thermostatic 
expansion 

valves 

(TXV), 

and 

scroll 

compressors.  
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
Never turn off the main power supply to the 
unit,  except  for  servicing,  emergency,  or 
complete shutdown of the unit. When power 
is  cut  off  from  the  unit  crankcase  heaters 
cannot prevent refrigerant migration into the 
compressors.  This  means  the  compressor 
may  cool  down  and  liquid  refrigerant  may 
accumulate 

in 

the 

compressor. 

The 

compressor  is  designed  to  pump  refrigerant 
gas  and  damage  may  occur  when  power  is 
restored. 
 
If  power  to  the  unit  must  be  off  for  more 
than  an  hour,  turn  the  thermostat  system 
switch  to  "OFF",  or  turn  the  unit  off  at  the 
control panel, and leave the unit off until the 
main power switch has been turned on again 
for  at  least  24  hours  for  units  with 
compressor crankcase heaters. This will give 
the crankcase heater time to clear any liquid 
accumulation out of the compressor before it 
is started.  
 
Always control the unit from the thermostat, 
or  control  panel,  never  at  the  main  power 
supply,  except  for  emergency  or  complete 
shutdown of the unit. 
 
During  the  cooling  season,  if  the  airflow  is 
reduced  due  to  dirty  air  filters  or  any  other 
reason,  the  cooling  coils  can  get  too  cold 
which  will  cause  excessive  liquid  to  return 
to 

the 

compressor. 

As 

the 

liquid 

concentration builds up, oil is washed out of 

 
 

 

CRANKCASE HEATER  

 

Some  units  are  equipped  with 
compressor 

crankcase 

heaters, 

which  should  be  energized  at  least 
24 hours prior to cooling operation, to 
clear  any  liquid  refrigerant  from  the 
compressors. 

 
 

  

 

CAUTION 

 

 
 

 

COMPRESSOR CYCLING 

 

5 MINUTE MINIMUM OFF TIME 

To 

prevent 

motor 

overheating 

compressors  must  cycle  off  for  a 
minimum of 5 minutes. 
 

5 MINUTE MINIMUM ON TIME 

To  maintain  the  proper  oil  level 
compressors  must  cycle  on  for  a 
minimum of 5 minutes. 
 
The  cycle  rate  must  not  exceed  6 
starts per hour. 

 
 

    

 

WARNING

 

Содержание SA-028

Страница 1: ...loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING WARNING QUALIFIED INSTALLER Improper installation...

Страница 2: ......

Страница 3: ...Heat Exchanger Cleaning 33 Electrical 33 Cutting Electrical Openings 34 Thermostat Control Wiring 35 Duct Connection 36 Condensate Drain Piping 36 Waterside Economizer 37 Hot Water Coil 41 Chilled Wat...

Страница 4: ...wnout Protection Module 51 Filter Replacement 53 Replacement Parts 54 AAON Warranty Service and Parts Department 54 Appendix A Heat Exchanger Corrosion Resistance 55 SA Series Startup Form 57 Maintena...

Страница 5: ...ails 22 Figure 5 One Piece Dual Unit Lifting Details 23 Figure 6 Two Piece Dual Unit Coil Section Lifting Details 24 Figure 7 Two Piece Dual Unit Fan Section Lifting Details 25 Figure 8 Dual unit with...

Страница 6: ...uld result in dangerous operation serious injury death or property damage Before servicing disconnect all electrical power to the unit More than one disconnect may be provided When servicing controls...

Страница 7: ...ng an Arc Flash Boundary to be field established and marked for identification of where appropriate Personal Protective Equipment PPE be worn should be followed WARNING UNIT HANDLING To prevent injury...

Страница 8: ...gen acetylene or air in place of refrigerant and dry nitrogen for leak testing A violent explosion may result causing injury or death WARNING Always use a pressure regulator valves and gauges to contr...

Страница 9: ...ooled condenser See Appendix A Heat Exchanger Corrosion Resistance for more information CAUTION OPEN LOOP APPLICATIONS Failure of the condenser as a result of chemical corrosion is excluded from cover...

Страница 10: ...unique to the model you have purchased 4 READ THE ENTIRE INSTALLATION OPERATION AND MAINTENANCE MANUAL OTHER IMPORTANT SAFETY PRECAUTIONS ARE PROVIDED THROUGHOUT THIS MANUAL 5 Keep this manual and all...

Страница 11: ...on Protection F Option C Interior Corrosion Protection A1 Refrigerant Style 0 Air Handling Unit B R 410A Non Compressorized DX AHU E R 410A Variable Capacity Scroll Compressor A2 Unit Configuration 0...

Страница 12: ...nomizer 6 Row Coil 1B Plenum Height 0 33 Plenum Height A 37 Plenum Height B 41 Plenum Height C 45 Plenum Height D 49 Plenum Height E 53 Plenum Height F 57 Plenum Height G 37 Plenum Height Sound Attenu...

Страница 13: ...ved Plenum 5C Supply Air Blower Motor C 1 hp 1760 rpm D 2 hp 1760 rpm E 3 hp 1760 rpm F 5 hp 1760 rpm G 7 5 hp 1760 rpm H 10 hp 1760 rpm N 1 hp 1170 rpm P 2 hp 1170 rpm Q 3 hp 1170 rpm R 5 hp 1170 rpm...

Страница 14: ...hers 5 Field Installed DDC Controls by Others with Isolation Relays 6 Factory Installed DDC Controls Furnished by Others with Isolation Relays 14A Water Cooled Condenser 0 Standard None A Balancing Va...

Страница 15: ...ld Adjustable for Glycol 16 Interior Cabinet Options 0 Standard A Overflow Switch B UV Lights C Options A B 17 Blank 0 Standard 18 Blank 0 Standard 19 Code Options 0 Standard ETL U S A Listing D Chica...

Страница 16: ...odes All appliances must be electrically grounded in accordance with local codes or in the absence of local codes the current National Electric Code ANSI NFPA 70 or the current Canadian Electrical Cod...

Страница 17: ...at system switch to OFF or turn the unit off at the control panel and leave the unit off until the main power switch has been turned on again for at least 24 hours for units with compressor crankcase...

Страница 18: ...of condensate lines Waterside economizer coil units include a separate condensate drain pan which drains into the evaporator coil drain pan No additional drain line is needed for the waterside economi...

Страница 19: ...clearance requirements Allow adequate space for piping access and panel removal Condenser water piping and condensate drain connections are near the bottom on the back of the unit Figure 1 SA Series...

Страница 20: ...20 Figure 2 One Piece Single Unit Lifting Details...

Страница 21: ...21 Figure 3 Two Piece Single Unit Coil Section Lifting Details...

Страница 22: ...22 Figure 4 Two Piece Single Unit Fan Section Lifting Details...

Страница 23: ...23 Figure 5 One Piece Dual Unit Lifting Details...

Страница 24: ...24 Figure 6 Two Piece Dual Unit Coil Section Lifting Details...

Страница 25: ...25 Figure 7 Two Piece Dual Unit Fan Section Lifting Details...

Страница 26: ...plete unit A crow bar or similar tool can be used to line up the sections Factory provided bolts can then be used to secure the coil sections together See Figure 9 4 Align and set each fan section on...

Страница 27: ...27 Figure 8 Dual unit without splices and before being bolted together Figure 9 Dual Unit Assembly Details...

Страница 28: ...28 Figure 10 Dual unit with splices after being bolted together...

Страница 29: ...s Any damage to the equipment as a result of condenser failure from chemical corrosion due the fluid in the condenser is excluded from coverage under AAON warranties and the heat exchanger manufacture...

Страница 30: ...l solution is recommended Table 2 Glycol Freezing Points Glycol Ethylene Glycol Propylene Glycol 20 18 F 19 F 30 7 F 9 F 40 7 F 6 F 50 28 F 27 F Water loop piping runs through unheated areas or outsid...

Страница 31: ...ust be controlled All make up water has minerals in it and as the water is evaporated in the cooling tower these minerals remain As the mineral content of the water increases the conductivity of the w...

Страница 32: ...GPM PSI 45 4 2 45 4 2 45 4 2 45 1 7 39 3 3 39 3 3 39 3 3 39 35 2 8 35 2 8 35 2 8 35 SA 045 SA 050 SA 055 SA 058 GPM PSI GPM PSI GPM PSI GPM PSI 45 4 2 45 4 2 45 4 2 45 4 2 39 3 3 39 3 3 39 3 3 39 3 3...

Страница 33: ...t of unit specific wiring diagrams showing factory and field wiring are laminated in plastic and located inside the controls compartment door All units require field supplied electrical overcurrent an...

Страница 34: ...e that the metal skins of the foam part do not separate from the foam this would result in reduced structural integrity of the part Size supply conductors based on the unit Minimum Current Ampacity MC...

Страница 35: ...determine the allowable wiring distances Table 5 Control Wiring Wire Size Stranded Copper Conductors Only Total Wire Distance Allowable 20 AWG 200 ft 18 AWG 350 ft 16 AWG 500 ft 14 AWG 750 ft 12 AWG 1...

Страница 36: ...may be equipped with more than one condensate drain pan connection A p trap and drain line must be installed on every drain connection with the p trap not to exceed 6 from the drain connection The lin...

Страница 37: ...hanical cooling only During waterside economizer only mode of operation condenser water flows through the waterside economizer coil with modulating valves maintaining supply air temperature setpoint T...

Страница 38: ...s of factory provided piping assemblies Connect the piping assembly to the unit Connect the actuators to the water valves Actuators are factory wired and included inside the unit Installing contractor...

Страница 39: ...ight Intake Piping Kit Left Intake Piping Kit Assembly 6 Assembly 1 Assembly 2 Assembly 3 Assembly 4 Assembly 5 Waterside Economizer Valve Waterside Economizer Bypass Valve Head Pressure Control Valve...

Страница 40: ...zer Back View Right Intake Piping Kit Left Intake Piping Kit Assembly 6 Assembly 1 Assembly 2 Assembly 3 Assembly 4 Assembly 5 Waterside Economizer Valve Waterside Economizer Bypass Valve Head Pressur...

Страница 41: ...ks on the performance of the unit This includes checking of the air flow the air filters condenser water flow and refrigerant charge Supply Fans SA Series units are equipped with direct drive backward...

Страница 42: ...bolt and rotate the locking nut counter clockwise approximately four full rotations This will allow the locking nut to spin when the adjustment bolt is turned See Figure 17 Turn adjustment bolt count...

Страница 43: ...wheels or with VFDs Field airflow adjustment may be required at startup Air volume bands for the wheels are sized according to the unit s air delivery specifications and can also be ordered from the...

Страница 44: ...nd equipped with easy bend tabs that are to be inserted into pre punched slots provided on the wheel Once the band has been inserted into the slots it MUST BE secured by bending the tabs over from the...

Страница 45: ...proper charge After charging unit should be operated in cooling mode to check for correct charge Charge may need to be adjusted for cooling mode If adjustments are made in the cooling mode heating mod...

Страница 46: ...ser Air Source Heat Pump Sub Cooling 12 18 F Sub Cooling with Hot Gas Reheat 15 22 F Superheat 8 15 F Water Cooled Condenser Water Source Heat Pump Sub Cooling 4 8 F Sub Cooling with Hot Gas Reheat 4...

Страница 47: ...87 261 4 114 384 6 141 547 0 34 105 0 61 172 5 88 265 4 115 389 9 142 553 9 35 107 1 62 175 4 89 269 4 116 395 2 143 560 9 36 109 2 63 178 4 90 273 5 117 400 5 144 567 9 37 111 4 64 181 5 91 277 6 11...

Страница 48: ...charge See Startup section for information on air flow adjustment and refrigerant charge adjustment DX Cooling Set unit controls to cooling mode of operation with supply fans on Check the fans for cor...

Страница 49: ...an e coated coil and is required to maintain coating warranty coverage Coil cleaning shall be part of the unit s regularly scheduled maintenance procedures Failure to clean an e coated coil will void...

Страница 50: ...ended that a hose be used as a pressure washer will damage the fins The water to be used for the rinse is recommended to be of potable quality though a lesser quality of water may be used if a small a...

Страница 51: ...the restart time delay All settings and the last 4 faults are retained even if there is a complete loss of power DPM Setup Procedure With the supply voltage active to the module you can setup all of t...

Страница 52: ...Screen Vertical Format Default 2 sec Manual 2S 3S 4S 5S 6S 7S 8S 9S 10S 30S 1M 2M 3M 4M Phase Imbalance Percentage Screen Vertical Format Default 5 3 4 5 6 7 8 9 10 Fault Screen Vertical Format 0 most...

Страница 53: ...Table 11 45 70 tons Pre Filters Feature 6A Quantity Size Type 0 No Pre Filters A 18 20 x 20 x 2 Pleated 30 Eff MERV 8 Table 12 23 35 tons Unit Filters Feature 6B Quantity Size Type 0 9 20 x 20 x 2 Ple...

Страница 54: ...number and part number when ordering parts AAON Warranty Service and Parts Department 2424 S Yukon Ave Tulsa OK 74107 Ph 918 382 6400 Fax 918 382 6364 www aaon com Note Before calling technician shoul...

Страница 55: ...orrosion problems may occur especially when more factors are valued 0 Use is not recommended Water Containing Concentration mg l or ppm Time Limits Analyze Before AISI 316 SMO 254 Copper Alloy Nickel...

Страница 56: ...t 0 2 0 Manganese Mn 0 1 No Limit 0 1 0 Chloride Content Chloride Content Maximum Temperature 60 C 140 F 80 C 176 F 120 C 248 F 130 C 266 F 10 ppm SS 304 SS 304 SS 304 SS 316 25 ppm SS 304 SS 304 SS 3...

Страница 57: ...es No 2 Is the unit level Yes No 3 Are the unit clearances adequate for service and operation Yes No 4 Do all access doors open freely and are the handles operational Yes No 5 Have all shipping braces...

Страница 58: ...sure PSIG Suction Pressure PSIG 1 2 3 4 Refrigeration System 1 Cooling Mode Pressure Saturated Temperature Line Temperature Sub cooling Superheat Discharge N A N A Suction N A Liquid N A Refrigeration...

Страница 59: ...A Liquid N A Refrigeration System 2 Heating Mode Heat Pump Only Pressure Saturated Temperature Line Temperature Sub cooling Superheat Discharge N A N A Suction N A Liquid N A Refrigeration System 3 He...

Страница 60: ...o 2 Has the entire system been filled with fluid Yes No 3 Has air been bled from the heat exchangers and piping Yes No 4 Is the glycol the proper type and concentration N A if water Yes No 5 Is there...

Страница 61: ...cument any service repair or adjustments AAON Service and Warranty Departments are available to advise and provide phone help for proper operation and replacement parts The responsibility for proper s...

Страница 62: ...adding the brazed plate heat exchanger cleaning instructions November 2012 Update of the IOM adding information about compressor cycling July 2013 Updated qualified installed warning and removed warr...

Страница 63: ...63...

Страница 64: ...Technical Support 918 382 6400 Note Before calling Technical Support please have the model and serial number of the unit available Parts For replacement parts please contact your local AAON Representa...

Отзывы: