OVERVIEW
1-8
Pioneer Gold 1.10 & 2.05 Controller Technical Guide
Pioneer Gold System Overview
PIONEER GOLD FEATURES & OPTIONS
UNIT CAPACITY
CONTROL
½ to 30 ton WSHPs
ADVANCED
ALARMS
•
Space Sensor Alarm
•
Air Flow Alarm
USER
INTERFACE
2.8” Touchscreen LCD Color Interface
with Two Levels of Security
Prism 2 Computer Software Interface
SERVICE AND
RELIABILITY
FEATURES
•
Firmware Update via USB Port
•
Fault and Status Indicator LED
•
Factory Wiring Harness Connectors
•
High/Low Control Voltage Lockout
(Auto Reset)
•
Alarm and Relay Status LEDs
•
Alarm Status - LCD Interface
STAND-ALONE
CAPABILITY
Stand Alone with Space Sensors or
Thermostat Terminals
NETWORKING
CAPABILITY
Built-In BACnet
®
MS/TP & BACnet
®
IP
(BACnet
®
IP for ASM02323 only)
MODBUS RTU
ADVANCED
FEATURES
•
Waterside Economizer Operation
•
Two-Speed EC Fan Operation
•
PSC Fan Control
•
Rotary or Scrolled Compressor
Control
•
Hot Gas Reheat Dehumidification
Control
•
Two-Step Compressor Operation
•
Motorized Water Valve Control
•
CAV Operation
•
Externally Controlled EC Motor
(0-10VDC)
•
Supply Air Temperature (SAT)
Staging Control
•
Supply Air Reset Control
•
Two Stage Auxiliary/Emergency Heat
•
BACnet
®
Compliant
•
Compressor Signal LED
•
Alarm Mode Indicator LED
•
2.8” Color Touchscreen LCD
Interface
•
Space Sensor Control
•
4.3” Color Pioneer Gold Touchscreen
Space Temperature and Humidity
Sensor (Optional)
BASIC
FEATURES
•
Thermostat Control
•
Random Start Delay
•
Compressor Minimum On/Off Timers
•
High Condensate Level Sensor
•
High Refrigerant Pressure Protection
•
Loss of Refrigerant Charge Protection
•
Reversing Valve Default to Heating Mode
•
Dry Alarm Contacts
•
Emergency Shutdown Input (not to be
used as a fire/life safety device)
•
Night Setback Mode
•
Night Setback Override Thermostat Input
•
High Condensate Level Sensor
•
Auxiliary Alarm Input
•
I/O Status LEDs
•
Occupancy Scheduling
•
7-Day, 2-Event-Per-Day Scheduling
BASIC
ALARMS
•
High/Low Control Voltage Alarms (24 VAC)
•
Air Coil Low Refrigerant
Temperature Alarm
•
Leaving Water Temperature Alarm
Table 1: Pioneer Gold Features & Options
Applications
The AAON
®
Pioneer Gold 1.10 & 2.05 Controller with Touch
Screen interface, BACnet
®
MS/TP, BACnet
®
IP (ASM02323 board
only), and ModBus RTU communication protocols is designed for
AAON
®
horizontal and vertical water-source heat pump units—WH
& WV series. All of the energy saving features and options available
on AAON
®
WH and WV Series water-source heat pumps can be
controlled with the Pioneer Gold Controller.
The Water-Source Heat Pump (WSHP) Pioneer Gold Controller
contains all the functionality required to operate basic and advanced
configurations of AAON
®
WH and WV Series WSHP units. The
controller can operate with a standard heat pump room thermostat
(by others) or can operate as a stand-alone system with the Pioneer
Gold Touchscreen Space & Humidity Sensor or Simple Space
Temperature Sensor.
The controller also contains a terminal block for communication
to the Pioneer Gold Electric Heat Board for additional heat stages.
NOTE:
If the application currently uses an obsolete mercury
bulb type thermostat, it must be upgraded to an elec-
tronic thermostat. The unit will not function properly
when controlled via a mercury bulb thermostat.
The controller has outputs to control a supply fan, compressor, and
reversing valve. It also provides I/O for additional functionality.
The Pioneer Gold is used for Constant Volume applications.