MiniLink PD 5 Technical Guide
13
APPENDIX B - MODULAR WIRING
Networked Multiple RS-485 Loop Modular System Wiring
Figure 9: MiniLink PD 5 RS-485 Networked Multiple Loop Modular System Wiring
Connect
To
Next
VA
V/Zone
Controller
On Branch
Circuit
T
ypical Networked Multiple Loop Modular System
With MiniLink Polling Devices &
VA
V/Zone Controllers
Power/Comm
Board
Line
V
oltage
Connect
To
Modular
I/O Connectors
Located On Back
Of
The System Manager
Modular System Manager SD
TB2
VAC
F1
25
4A
24
SHLD
T
R
POWER
LD1
TB1
C1
POWER & COMM
DIST. BOARD
YS101856
REV. 0
P5
P4
P3
P1
D1
V1
R1
P2
COMMP
IN
POWER & COMM
OUT
Connect
To
Other
VA
V/Zone
Controllers
On Loop
Connect
To
Other
VA
V/Zone
Controllers
On Loop
Connect
To
Other
VA
V/Zone
Controllers
On Loop
Power/Comm
Board
Line
V
oltage
Class 2 100
VA
Max
24 V
AC - Size
T
ransformer For
Required
VA
Load
Note: For
VA
V/Zone BACnet
Controllers
,A
Maximum Of 4 Can Be Connected
To
Each Branch
Circuit.
AT
otal Of 8 Controllers
Are
Allowed Per
Power/Comm Board. Use
Additional Power/Comm
Boards For Systems
That Exceed 8 Controllers.
®
For
Previous Generation
VA
V/Zone Controllers
,A
Maximum Of 6 Can Be Connected
To
Each Branch
Circuit.
AT
otal Of 16 Controllers
Are
Allowed Per
Power/Comm Board. Use
Additional Power/Comm
Boards For Systems
That Exceed 16 Controllers.
TB2
VAC
F1
25
4A
24
SHLD
T
R
POWER
LD1
TB1
C1
POWER & COMM
DIST. BOARD
YS101856
REV. 0
P5
P4
P3
P1
D1
V1
R1
P2
COMMP
IN
POWER & COMM
OUT
Connect
To
Loop 2 Power/
Comm Board
& HV
AC Unit
Controller
110 V
AC
To
24
VA
C
Power Pack
Note:
CommLink Must Be Set
For Multiple Loop Operation
HV
AC
Unit Controller
(VCCX2 shown)
Modular Service
T
ool SD
Back V
iew of CommLink
5
Front V
iew of CommLink
5
Note:
Either
A
Modular System Manager SD,
Modular Service
T
ool SD, Or PC With Prism
2
Software Installed Can Be Used
To
Program
And Configure
The Orion System.
System Manager TS-L
Network
Connect
To
Loop
3
MiniLink PD
5
Network
Local
Local
18-30
VA
C
(6
VA
)
MiniLink PD 5 Loop
1
PD DRV
LOOP DRV
NET
DR
V
PIC32 MLPD
YS102398 REV
3
NETWORK
LOCAL
PD COMM
POWER
1
2
4
8
16
32
COMM
ADDRESS
ML
PD
MADE IN USA
SERIAL #
C2
2
C2
3
C3
0
C3
7
C4
0
J1
J3
R1
R2
R3
R4
R2
0
R2
1
R22
R2
3
R2
4
R25
R2
6
R2
7
R3
1
PDST
AT
1
PDST
AT
2
SW
2
TB
1
TB
2
U8
U1
0
U12
D4
J6
J7
J8
R4
3
R4
4
R4
6
C33
OFF
T
SH
R
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
.1uF
.1u
F
.1uF
.1u
F
1002
1002
T
SH
R
C2
4
COMM
Network
Network
Local
18-30
VA
C
(6
VA
)
MiniLink PD 5 Loop
2
PD DRV
LOOP DRV
NE
TD
RV
PIC32 MLPD
YS102398 REV
3
NETWOR
K
LOCAL
PD COM
M
POWE
R
1
2
4
8
16
32
COM
M
ADDRESS
ML
PD
MADE IN US
A
SERIAL #
C2
2
C2
3
C3
0
C3
7
C4
0
J1
J3
R1
R2
R3
R4
R2
0
R2
1
R22
R2
3
R2
4
R25
R2
6
R2
7
R3
1
PDST
AT
1
PDST
AT
2
SW
2
TB
1
TB2
U8
U1
0
U12
D4
J6
J7
J8
R4
3
R4
4
R4
6
C33
OFF
T
SH
R
100
2
100
2
100
2
100
2
100
2
1002
1002
1002
100
2
1002
100
2
1002
100
2
100
2
1002
1002
1002
1002
1002
1002
.1uF
.1uF
.1uF
.1uF
1002
1002
T
SH
R
C2
4
COM
M
18-30
VA
C
(15
VA
)
Note:
The SMTS-L
Is
An
End-User Interface Only
.
It Cannot Be Used
To
Configure
The Controllers.
VA
V/Zone
Controller Package
(V
A
V/Zone w/ BACnet
shown
w/ Modular
Adapter
®
)
Line
Vo
ltage
Line
Vo
ltage
MULTIPLE
HIGH
SINGLE
LOW
BAUD
R (+)
SHLD
T (-)
SERIAL
#
24VAC
GND
LOOP
2D
BARCODE
SOFTW
ARE
VA
V/Zone
Controller Package
(V
A
V/Zone w/ BACnet
shown)
w/ Modular
Adapter
®
ALARM
UP
DOW
N
ENTER
MENU
ALARM
UP
DOW
N
ENTE
R
MENU
Line
Vo
ltage
24 V
AC - Size
T
ransformer For
Required
VA
Load
Class 2 100
VA
Max
SHLD
T
R
T
ypical T
erminal Blocks.
All
Wiring
To
Be T
To
T,
SHLD (G)
To
SHLD (G) & R
To
R
T
G
R
RS-485 LOOP