Controller, Sensors & Related Hardware
Components
GPC-XP Controller
OE338-23-GPCXP
The OE338-23-GPCXP Controller is used for controlling equipment or processes that cannot be controlled us-
ing a standard HVAC controller. The Prism 2 computer front end software is required to interface with the GPC-
XP controller functions. The GPC-XP Controller provides the flexibility to control, schedule and/or monitor equip
-
ment such as unit heaters, exhaust fans, motorized louvers, boilers, pumps and other mechanical equipment.
• 8 configurable analog inputs
• All analog inputs accept 10 K ohm thermistor sensors, 4-20 mA, 0-5 VDC or 0-10 VDC signals and
are set by means of jumpers on the controller
• Create custom formulas for analog inputs
• Highest/lowest/average of the analog inputs. Can be used in the internal logic or can be broadcast to
other controllers on the system
• 8 wet 24 VAC binary contacts which can be configured for N.O. or N.C. operation
• 8 configurable N.O. or N.C. relay outputs for On/Off control of equipment
• 4 analog outputs with proportional control signals. All selectable for 0-10 VDC output
• 8 separate 2 event per day time schedules which can be used for operational control or alarm
recognition based on time of day
• Lead/lag start capabilities.
Duct Temperature Sensor - 6” Probe
OE230
Used for return or supply air water sensing applications. 10k Ohm Duct Temperature Sensor, 2 wire. Used with
OE291 immersion well listed below
Immersion Well for OE230 Water Temperature Sensor
OE366
Includes: Stainless steel thermowell to be used with the OE230 Temperature Sensor listed above. The ther-
mowell is designed to thread into a ½″ FPT elbow or tee in the water piping system.
Strap-on Temperature Sensor Kit
OE233
10k Ohm Type 3, Strap-on Temperature Sensor, 2 wire. Used for water temperature sensing on outside of pipe.
Includes sensor, thermal mastic, and plastic mounting strap.
Outdoor Air Temperature Sensor
OE250
Used for temperature sensing applications. 10k Ohm Outside Air Temperature Sensor, 2 wire, mounted in a
weatherproof handy box only.
Outdoor Air Mounted RH Sensor 3% - 0-5 VDC Output
OE265-13
Used for outdoor air humidity sensing applications.
Water Differential Pressure Transducer
OE262
Includes: 0-5 VDC Differential Pressure Transducer and mounting bracket. The water pressure transducer
is used with the WSHP Loop Controller to detect water flow differential pressure in the system water loop.
Required when a VFD pump is used..
Water Differential Pressure Switch
OE261
Includes Differential Pressure Switch only. This SPDT switch is used with the WSHP Loop Controller to detect
flow in the system water loop.
8
WSHP Loop Controller
GPC-XP Guide