F-08-X: Memory
Items to call up from ID memory
◄
Unit weight (and item code) only
Set data for total, upper and lower limits, and tare with 0 and 1 to
select items to call up.
“ ”: Not to call up
“ ”: Call up
Ex.) The setting “
” calls up unit weight (and item code) and upper and
lower limits.
Select internal memory or external memory
◄
Internal memory
External memory
F-09-X: Function assignment
key operation
◄
Switch ID and item code.
Operate as the M- key.
Display switch
◄
Main display: Count
Sub display: Weight
Main display: Weight
Sub display: Count
F-10-X: External input terminal
: Key to assign to external input signal #1
: Key to assign to external input signal #2
Ready a 3.5 mm stereo mini plug (not included in the package) and connect it to a switch,
etc. It works by short-circuiting #1 or #2 with GND (100ms or greater).
◄
RESET (the factory setting of
)
◄
ENTER (the factory setting of
)
TARE
ZERO
SAMPLE
REMOTE SCALE
TOTAL
M+
GND terminal
Terminal #2
Terminal #1
#1
#2
GND
3.5 mm stereo mini plug
Model number: NYS231B Manufacturer: REAN
*An equivalent is usable.
Total
Upper and lower limits
Tare