1. INTRODUCTION
This manual describes how the AD-4212C series balance works and how to get the most out of it in
terms of performance.
Read this manual thoroughly before using the balance and keep it at hand for future reference.
1.1. Features
z
A Weighing Unit, suitable for building into a production line system. The weighing unit is
compact, with a width of 59 mm.
z
A Super Hybrid Sensor (SHS) is used to provide high resolution and high response speed.
Model
Weighing
capacity
Minimum
weighing
value
Stabilization time
*1
AD-4212C-300
320 g
0.001 g
0.5 second (0 - 30 g), 1.0 second (30 - 320 g)
AD-4212C-600
620 g
0.001 g
0.5 second (0 - 30 g), 1.0 second (30 - 620 g)
AD-4212C-3000
3200 g
0.01 g
0.5 second (0 - 300 g), 1.0 second (300 - 3200 g)
AD-4212C-6000
6200 g
0.01 g
0.5 second (0 - 300 g), 1.0 second (300 - 6200 g)
51 g
*2
0.0001 g
1.3 seconds
AD-4212C-301
320 g
0.001 g
1.0 second
510 g
*2
0.001 g
1.3 seconds
AD-4212C-3100
3200 g
0.01 g
1.0 second
*1
With FAST selected under good environment
*2
Smart range (Refer to “5. SMART RANGE FUNCTION”.)
z
The AD-4212C series can output the weighing digital data directly. Therefore, the AD-4212C
series (the weighing unit) can be connected to a personal computer or a PLC directly.
z
Dust-protected and Protected Against Splashing Water (Complying with IP65). The AD-4212C
series has a patented shock absorber under the weighing pan and can cope with movement in
all directions, protecting the weighing unit from an actuator malfunction.
z
Windows Communication Tools (WinCT-AD4212C), allows easy confirming of the weighing
data by using a Windows-based personal computer.
Windows is a registered trademark of the Microsoft Corporation.
z
When connected to an optional remote controller, an AD-8922A, AD-8923-BCD or AD-8923-CC,
the remote controller can receive the weighing data and manually perform re-zero and
calibration.
The AD-8922A can output the data using BCD, comparator or analog out by selection of the
option installed in the AD-8922A.
The AD-8923-BCD outputs the data using BCD and the AD-8923-CC outputs the data using
CC-Link.
Note: CC-Link is a high-speed field network able to simultaneously handle both control and
information data.
z
When connected to an optional AD-8526 Ethernet converter, it can convert the AD-4212C
RS-232C data, for output to a local area network (LAN).