Installation and Operating Instructions 

 

Read These Warnings First 

 

 

 

 

 

 

 

 

EZYTAP

 

The EZYTAP75/75T comes with a High Performance 4ltr Undersink Boiler. It also dispenses Ambient Water. 

The EZYTAP85/85T comes with a High Performance 8ltr Undersink Boiler. It also dispenses Ambient Water. 

The EZYTAP7800/7800T comes with a high performance 4ltr Undersink Boiler. By adding an Undersink Chiller 
(UC800M) it also dispenses Chilled Water. 

The EZYTAP8800/8800T comes with a high performance 8ltr Undersink Boiler. By adding an Undersink Chiller 
(UC800M) it also dispenses Chilled Water. 

The EZYTAP75/85/7800/8800 have a dispensing height of 18.5cm.  

The EZYTAP75T/85T/7800T/8800T have a dispensing height of 24cm. 

The Undersink Chiller (UC800M) can be replaced by any of the Cosmetal Undersink Chillers H20MY IN (CEH2IN15), J 
CLASS IN (CEJIN45), Nigara IN (CENIN120C8). Please note you will need some different connections if using these 
models. 

 

 

UNIQUE SCALE PREVENTION SYSTEM 

The EZYTAP has two separate mains water inlets. One feeding the Boiler and the other feeding the Ambient or 
Chilled side. This provides the unique opportunity to protect the Boiler from scale by connecting a proper Scale 
removal Filter to the Boiler water inlet side whilst connecting the Ambient or Chilled inlet to a simple odour and 
taste Carbon Block Filter.  

In Hard Water Areas the Scale removal Filter will reduce the need for regular descaling. Separately connecting the 
Ambient or Chilled water inlet to a Carbon Block Filter will avoid reducing the life of the Scale Inhibiting Filter by the 
amount of cold water that would flow through it if the Scale Inhibiting Filter was to serve both sides. 

In a soft water area, the EZYTAP only requires a SINGLE Carbon Block Filter to connect to the mains water inlets. 

 

 

Please read all installation requirements, installation procedures 

and precautions before installing the EZYTAP water boiler. 

 

Never attempt to install any water dispenser without reading all of 

the applicable instructions. 

 

All electrical connections must comply with current wiring rules. 

 

This appliance is not designed for use by young children without 

supervision. 

 

This appliance must be earthed. 

 

If the power supply cord is damaged, it must be replaced by a 

qualified electrician. 

 

Do not remove the cover of the appliance under any circumstances 

without first isolating the appliance from the power supply. 

Содержание EZYTAP Series

Страница 1: ...Installation and Operating Instructions 1 EZYTAP Range Installation and Operating Instructions...

Страница 2: ...Installation and Operating Instructions 2 EZYTAP Range Breakdown...

Страница 3: ...unique opportunity to protect the Boiler from scale by connecting a proper Scale removal Filter to the Boiler water inlet side whilst connecting the Ambient or Chilled inlet to a simple odour and tas...

Страница 4: ...ter Pressure Max 50 PSI Tank Capacity 4 2 Litres Power 2000 Watts Mains Water Supply to Boiler Chilled Water to Cold In on Boiler via SVKIT Hot Water Outlet to Tap Hot Water Outlet to Tap Mains Water...

Страница 5: ...Instructions 5 Filter Configuration for Hard Soft Water EZYTAP 7800 7800T 8800 8800T Boiler Chiller and Tap EZYTAP In Hard Water Area EZYTAP In Soft Water Area EZYTAP In Hard Water Area EZYTAP 75 75T...

Страница 6: ...in relation to each other and to the TAP and mains inlet that the connecting hoses are not twisted or kinked NOTE Do not lengthen the hoses as this could impair performance You must PRIME THE HOT TAN...

Страница 7: ...75T See Page 7 for more information SAFETY VALVE KIT SVKIT INSTALLATION INSTRUCTIONS WITH THE UC800M UNDERSINK CHILLER The Safety Valve Kit is supplied the UC800M Under sink Chiller It MUST be instal...

Страница 8: ...Boiler for ease of handling 3 Drain the Boiler from underneath by unscrewing the drain cap Once drained re fit the drain cap 4 Using a funnel to pour the Descaling Solution into hot water outlet at th...

Страница 9: ...r boiler of the Ezytap75 7800 range This has implications for installation and servicing Please refer back to the EZYTAP Range Installation and Operating Instructions Apart from the high capacity 8 Li...

Страница 10: ...ot Water Outlet to Tap Vent Connected to Tap Cold Water Supply Inlet Cold Water Outlet to Tap Cold Water Supply to Boiler Hot Water Outlet to Tap Vent Connected to Tap Cold Water Supply Inlet Cold Wat...

Страница 11: ...islation NOTE The Boilers and Chillers must be so positioned in relation to each other and to the TAP and mains inlet that the connecting hoses are not twisted or kinked NOTE Do not lengthen the hoses...

Страница 12: ...a J Guest length of pipe to connect from OUT on the UC800M to the COLD IN on the EZYTAP75 75T See Page 7 for more information SAFETY VALVE KIT SVKIT INSTALLATION INSTRUCTIONS WITH THE UC800M UNDERSIN...

Страница 13: ...uter casing by unscrewing the screws holding the boiler casing in place and carefully remove the boiler casing and set it aside 5 For 85 8800 expose the level probes by locating the 3 level probes on...

Страница 14: ...d Operating Instructions 14 Error codes 85 T 8800 T Distributed by Cedar House Grange Farm Long Lane Newbury RG14 2TF TEL 44 0 01635 202489 FAX 44 0 01635 202499 E Mail enquiries aafirst co uk http ww...

Отзывы: