Installation and Operating Instructions
12
EZYTAP 85(T)/8800(T) Installation Instructions & Tips
The tap rotates 30 degrees each side. You can stop it rotating.
1.
Rotate tap fully to one side.
2.
Carefully remove grub screw at rear of tap.
3.
Rotate tap a little further round and screw in grub screw.
4.
If the grub screw can only be half screwed in, the tap should be secure and no longer rotate.
5.
For ease of access to the grub screw, it is recommended that the tap rotation is fixed before installation.
Hot water is not hot enough.
Two dashes displayed on the tap instead of the “H” sign. This shows that the boiler has been turned off, maybe
accidently. To re- set, press and hold ‘Power’ button for 8-10 seconds.
Sleep Mode
Sleep mode can be activated when the boiler is powered on (H is displayed)
Sleep mode will disable the boiler/heating for 6 hours.
To activate sleep mode press and hold the safety button for 6 seconds. The display will show
EC.
To disable sleep mode press and hold the Safety button for 6 seconds. (The H is displayed)
How to connect the mains water from the UC800M Chiller to the EZYTAP75/75T or EZYTAP85/85T Boiler to create
the EZYTAP7800/7800T or EZYTAP8800/8800T
– Connect the ¼” J Guest pipe from the carbon filter to the ‘IN’
connection on the UC800M. Use a J Guest length of pipe to connect from ‘OUT’ on the UC800M to the ‘COLD IN’ on
the EZYTAP75/75T. (See Page 7 for more information)
SAFETY VALVE KIT (SVKIT) INSTALLATION INSTRUCTIONS WITH
THE UC800M UNDERSINK CHILLER
The Safety Valve Kit is supplied the UC800M Under-sink Chiller. It MUST be installed with all UC800M chillers.
The SVKIT is designed to protect the Under-sink Installation from excessive pressure in the water system, because of ice build-up in the water
tank, by venting water into a waste outlet. Failure to install the Safety Valve Kit could lead to a failure of fittings and pipework and potentially
lead to a leak.
Installation Instructions:
•
Install the Safety Valve Kit between the outlet of the Chiller and the Tap (see illustration). The Safety Valve will release the pressure
build up from expanded ice in the water tank by venting water into a waste.
•
Using a 9.5mm drill bit, drill a hole in the side of the plastic sink waste drain. Then fit a PV36 14.3mm Grommet supplied into the
drilled hole. Push John Guest ¼ “pipe from safety valve outlet into Grommet in sink waste drain.
•
If there is no sink waste pipe available, we suggest you connect the pipe to a waste bottle that’ should be checked periodically and
emptied.
•
The SVKIT does not include a JG ¼” drain pipe which connects the SVKIT to the waste outlet (a quantity of pipe is already supplied
with the UC800 equipment). Please note if no waste outlet is available the vent can be fed into a jerrycan.