![AADI RDCP600 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/aadi/rdcp600/rdcp600_deployment-manual_448467055.webp)
JANUARY 2010 - TD 220a DEPLOYMENT GUIDE, RDCP600
Page
55
Reliable solutions
2.1.2
Data Storage
To store the Wave parameters, Wave Time series
and/or the Wave Spectrum, check the parameters in the
Sensor
page of the
Data Storage Configuration
,
refer
Figure 2-3.
NOTE! The Wave timeseries/spectrum parameter holds
a large amount of data, hence occupies a large part of
the storage capacity. Storing the parameter consumes a
lot of power. In some cases storage of wave time
series/spectrum will slow down the system. Wave
timeseries/spectrum should only be recorded in special
occasions.
The Raw Wave data are given in [Pa], and are sampled
at 2 Hz intervals.
2.1.3
Real-Time Output
Real-Time output of Wave spectrum and wave timeseries via PDC-4 is not possible (due to time
consumption). Other wave parameters can be sent real-time via PDC-4.
Descriptions of the RS protocols (for real-time output) are given in TD220c
RDCP Primer
.
2.1.4
Operating Instructions
Mount the supplied pressure stopper to protect the Quartz pressure sensor if the RDCP 600 is
deployed at depths greater than the specified maximum depth for the Quartz pressure sensor.
IMPORTANT! Higher pressure than normal at the specified maximum depth can destroy the
Quartz Pressure sensor. Mount the supplied pressure stopper if the instrument is deployed at
greater depths than specified by the sensor.
Figure 2-3 Data storage.