4.3 EXM Web Control Interface
4.3.1 System menu
The following [System] menu
should appear when you connect
to the ESX-200. The [System]
menu contains basic information
about current settings and
entitlements.
Menu buttons for [Input],
[Output], [IPTV], [Service
management] , [CI] and [Upload]
are available in top of the menu.
4.3.2 IP address settings
The ESX-200 is set to an default IP address from factory (192.168.0.20 ). However,
it is possible to change the IP address and/or the Netmask and/or the Gateway. This
is an important function when you install two or more EXM units in a Head End and
want to connect all units together through a switch or a router.
4. Settings (continued)
Current settings
Contains information of current input and output signals, if the tuner is
locked to a signal, serial number and firmware revision.
Entitlements
Entitlements are software options that are available in this unit (e.g. output
signal format, input signal entitlements etc.)
System options
This menu contains current IP address for the ESX-200.