background image

5.Installation

4.  Dimensions

Then  isolate  them  with  a  suitable  insulating  
tape  (not  included).

3.  Connect  the  solar  panel  with  the  positive  

4.  Check  the  status  of  the  

LED  display  (see  section  10).

corresponding  cables  

(positive  pole=red  (1) //  negative  pole=black  (2)).

1.  First  connect  the  load  with  the

Make  sure  the  cable  lengths  between  the  
battery  and  the  controller  are  as  short  as  
possible.  Make  sure  that  the  cable  cross-
section  is  sufficient  and  that  you  connect  
it  in  the  correct  order:

The  controller  starts  

charging.

MPPT  solar  charge  controller  X45/10

operation  manual

page  7

02/2022

Machine Translated by Google

2.  Then  connect  the  battery.

It  applies  again
(positive  pole=red  (3) //  negative  pole=black  (4)).

cable  (5)  and  the  negative  cable  (6).

The  load  should  now  be  switched  on.

Содержание X45/10

Страница 1: ...Installation and Operating instructions a TroniX MPPT solar charge controller X45 10 02 2022 page 1 9887579 model item number a Tronix MPPT solar charge controller X45 10...

Страница 2: ...ord GmbH cannot be held responsible for any inaccuracies or inappropriate information in these operating instructions We reserve the right to make design and device changes that serve to improve the p...

Страница 3: ...f Test 9 10 LED indicator 12 12 7 6 Commissioning of the controller 8th 8 1 Charging Voltage Wet Gel AGM 9 Loading modes 9 15 5 8 4 Low Voltage Reclosing LVR 8 5 0 C Charge Lithium 9 4 Manual operatio...

Страница 4: ...es are identified by the appropriate symbols pictograms and must be observed otherwise they will be lost Danger high voltage ENVIRONMENT Make use of the certified and professional recycling service of...

Страница 5: ...relevant laws Otherwise personal injury or equipment damage may occur The solar charge controller may only be used in photovoltaic systems that comply with these operating instructions Likewise only...

Страница 6: ...e Maximum Power Point Tracking MPPT technology Automatic activation of the BMS when due to LVD 5 level load output timer Robust and durable aluminum housing High charge conversion efficiency of up to...

Страница 7: ...th the Make sure the cable lengths between the battery and the controller are as short as possible Make sure that the cable cross section is sufficient and that you connect it in the correct order The...

Страница 8: ...in the App Store iOS For detailed explanations and settings please read the user manual of the Bluetooth app Apple It then automatically switches to normal operation If the controller is set to gel w...

Страница 9: ...Voltage 1 5V Lithium Overcharge Protection Voltage Overcharge Recovery Voltage 0 2V You can set the overcharge protection and overcharge recovery voltage of the lithium battery through the app Overch...

Страница 10: ...1 4 to 12 8 V SoC SoC 3 If you want to change the LVD you must first change the LVR The low voltage protection of the controller can be divided into two types a Battery voltage control Low voltage cut...

Страница 11: ...open circuit voltage of the solar system the charge controller recognizes day and night The day night threshold can be adjusted depending on the lighting conditions Battery cannot be charged The load...

Страница 12: ...stem then takes at time 4 the data from time 5 and previous data about the time of sunrise With this charging mode the day night threshold values and the day night delay can be set The load can be swi...

Страница 13: ...ion Equal or reinforced charge Overvoltage protection Fast flashing 0 1 0 1s The output power is 0 LEDs Slow blinking 0 5 2s Charging Works normally If the controller turns off the load due to under v...

Страница 14: ...is probably damaged Check battery performance and battery fuse Battery not charging links remedy Charge battery via LVR The controller turns off the system until the temperature falls below 60 C at th...

Страница 15: ...per cell boost equalization 3 33mV K per cell float Protected Protected MPPT charge voltage and Lithium Wet Gel AGM Default Gel 15 5V Protected 1 countercurrent Turns off immediately 1 Controller can...

Страница 16: ...the PV connection battery voltage 1 0V Voc 0 9 1 Maximum charge conversion ambient temperature lithium 45V output current 8mA 4 000m Turn on low voltage again 9 6 16 0V programmable Maximum tracking...

Отзывы: