background image

When  setting  the  load  mode  to  "always  on",  the  load  is  always  on  unless  the  

protection  state  is  present.

Times  1-5  can  be  set  individually  to  allow  variable  load  performance  at  night.  if  e.g.  
B.  Time  4  is  set  to  "TOT" (Time/Operation/Time),  time  4  is  removed.  The  system  

then  takes  at  time  4  the  data  from  time  5  and  previous  data  about  the  time  of  
sunrise.

With  this  charging  mode,  the  day/night  threshold  values  and  the  day/night  delay  
can  be  set.  The  load  can  be  switched  on  or  off  by  the  test  function  during  the  day  

during  the  charging  process.

02/2022

page  12

operation  manual

MPPT  solar  charge  controller  X45/10

9.2  Mode:  Dusk  to  Sunrise

9.3  5-level  mode

Machine Translated by Google

9.  Charge Modes

9.1  Mode:  Always  on

Содержание X45/10

Страница 1: ...Installation and Operating instructions a TroniX MPPT solar charge controller X45 10 02 2022 page 1 9887579 model item number a Tronix MPPT solar charge controller X45 10...

Страница 2: ...ord GmbH cannot be held responsible for any inaccuracies or inappropriate information in these operating instructions We reserve the right to make design and device changes that serve to improve the p...

Страница 3: ...f Test 9 10 LED indicator 12 12 7 6 Commissioning of the controller 8th 8 1 Charging Voltage Wet Gel AGM 9 Loading modes 9 15 5 8 4 Low Voltage Reclosing LVR 8 5 0 C Charge Lithium 9 4 Manual operatio...

Страница 4: ...es are identified by the appropriate symbols pictograms and must be observed otherwise they will be lost Danger high voltage ENVIRONMENT Make use of the certified and professional recycling service of...

Страница 5: ...relevant laws Otherwise personal injury or equipment damage may occur The solar charge controller may only be used in photovoltaic systems that comply with these operating instructions Likewise only...

Страница 6: ...e Maximum Power Point Tracking MPPT technology Automatic activation of the BMS when due to LVD 5 level load output timer Robust and durable aluminum housing High charge conversion efficiency of up to...

Страница 7: ...th the Make sure the cable lengths between the battery and the controller are as short as possible Make sure that the cable cross section is sufficient and that you connect it in the correct order The...

Страница 8: ...in the App Store iOS For detailed explanations and settings please read the user manual of the Bluetooth app Apple It then automatically switches to normal operation If the controller is set to gel w...

Страница 9: ...Voltage 1 5V Lithium Overcharge Protection Voltage Overcharge Recovery Voltage 0 2V You can set the overcharge protection and overcharge recovery voltage of the lithium battery through the app Overch...

Страница 10: ...1 4 to 12 8 V SoC SoC 3 If you want to change the LVD you must first change the LVR The low voltage protection of the controller can be divided into two types a Battery voltage control Low voltage cut...

Страница 11: ...open circuit voltage of the solar system the charge controller recognizes day and night The day night threshold can be adjusted depending on the lighting conditions Battery cannot be charged The load...

Страница 12: ...stem then takes at time 4 the data from time 5 and previous data about the time of sunrise With this charging mode the day night threshold values and the day night delay can be set The load can be swi...

Страница 13: ...ion Equal or reinforced charge Overvoltage protection Fast flashing 0 1 0 1s The output power is 0 LEDs Slow blinking 0 5 2s Charging Works normally If the controller turns off the load due to under v...

Страница 14: ...is probably damaged Check battery performance and battery fuse Battery not charging links remedy Charge battery via LVR The controller turns off the system until the temperature falls below 60 C at th...

Страница 15: ...per cell boost equalization 3 33mV K per cell float Protected Protected MPPT charge voltage and Lithium Wet Gel AGM Default Gel 15 5V Protected 1 countercurrent Turns off immediately 1 Controller can...

Страница 16: ...the PV connection battery voltage 1 0V Voc 0 9 1 Maximum charge conversion ambient temperature lithium 45V output current 8mA 4 000m Turn on low voltage again 9 6 16 0V programmable Maximum tracking...

Отзывы: