background image

Failure  to  take  preventive  protective  measures  may  result  in  damage  to  the  product  

and/or  its  functions  or  something  in  its  vicinity.

Accumulators  are  usually  used  as  energy  stores  in  a  PV  system .  These  are  colloquially  

referred  to  as  rechargeable  batteries  or  batteries.

NOTE:

Solar  charge  controllers  are  used  in  conjunction  with  a  photovoltaic  system.  These  are  also  

referred  to  as  PV  systems.

This  symbol  indicates  text,  hints  or  tips.

Injury  or  death  can  result:

Indicates  information  about  recycling.

Warnings  and  notes  are  identified  by  the  appropriate  symbols  (pictograms)  and  must  be  

observed,  otherwise  they  will  be  lost

Danger  high  voltage.

ENVIRONMENT:

Make  use  of  the  certified  and  professional  recycling  service  of  

our  AKKU  SYS  team.

WARNING!

Identifies  assemblies  or  parts  that  must  be  disposed  of  properly.  Do  not  throw  them  
in  the  household  waste.

Warning  when  handling  accumulators.

In  this  manual,  the  abbreviation  MPPT  stands  for:  Maximum  Power  

Point  Tracking.

on  the  hotline  +49  4101/376760,  

[email protected]  

or  use  the  QR  

code:

General  warning  of  danger  spots.

1.  Symbols  and  abbreviations  used

page  

4

02/2022

MPPT  solar  charge  controller  X45/10

operation  manual

For  more  information  contact  us  by  phone

Machine Translated by Google

Содержание X45/10

Страница 1: ...Installation and Operating instructions a TroniX MPPT solar charge controller X45 10 02 2022 page 1 9887579 model item number a Tronix MPPT solar charge controller X45 10...

Страница 2: ...ord GmbH cannot be held responsible for any inaccuracies or inappropriate information in these operating instructions We reserve the right to make design and device changes that serve to improve the p...

Страница 3: ...f Test 9 10 LED indicator 12 12 7 6 Commissioning of the controller 8th 8 1 Charging Voltage Wet Gel AGM 9 Loading modes 9 15 5 8 4 Low Voltage Reclosing LVR 8 5 0 C Charge Lithium 9 4 Manual operatio...

Страница 4: ...es are identified by the appropriate symbols pictograms and must be observed otherwise they will be lost Danger high voltage ENVIRONMENT Make use of the certified and professional recycling service of...

Страница 5: ...relevant laws Otherwise personal injury or equipment damage may occur The solar charge controller may only be used in photovoltaic systems that comply with these operating instructions Likewise only...

Страница 6: ...e Maximum Power Point Tracking MPPT technology Automatic activation of the BMS when due to LVD 5 level load output timer Robust and durable aluminum housing High charge conversion efficiency of up to...

Страница 7: ...th the Make sure the cable lengths between the battery and the controller are as short as possible Make sure that the cable cross section is sufficient and that you connect it in the correct order The...

Страница 8: ...in the App Store iOS For detailed explanations and settings please read the user manual of the Bluetooth app Apple It then automatically switches to normal operation If the controller is set to gel w...

Страница 9: ...Voltage 1 5V Lithium Overcharge Protection Voltage Overcharge Recovery Voltage 0 2V You can set the overcharge protection and overcharge recovery voltage of the lithium battery through the app Overch...

Страница 10: ...1 4 to 12 8 V SoC SoC 3 If you want to change the LVD you must first change the LVR The low voltage protection of the controller can be divided into two types a Battery voltage control Low voltage cut...

Страница 11: ...open circuit voltage of the solar system the charge controller recognizes day and night The day night threshold can be adjusted depending on the lighting conditions Battery cannot be charged The load...

Страница 12: ...stem then takes at time 4 the data from time 5 and previous data about the time of sunrise With this charging mode the day night threshold values and the day night delay can be set The load can be swi...

Страница 13: ...ion Equal or reinforced charge Overvoltage protection Fast flashing 0 1 0 1s The output power is 0 LEDs Slow blinking 0 5 2s Charging Works normally If the controller turns off the load due to under v...

Страница 14: ...is probably damaged Check battery performance and battery fuse Battery not charging links remedy Charge battery via LVR The controller turns off the system until the temperature falls below 60 C at th...

Страница 15: ...per cell boost equalization 3 33mV K per cell float Protected Protected MPPT charge voltage and Lithium Wet Gel AGM Default Gel 15 5V Protected 1 countercurrent Turns off immediately 1 Controller can...

Страница 16: ...the PV connection battery voltage 1 0V Voc 0 9 1 Maximum charge conversion ambient temperature lithium 45V output current 8mA 4 000m Turn on low voltage again 9 6 16 0V programmable Maximum tracking...

Отзывы: