ACTIVATE /
PARM
DEACTIVATE
CHARACTERISTIC
ATTITUDE
DRM0
Socket activated by shorting the pins
Don't consume power.
Do not generate more than 75% of the rated power and remove
reactive power if possible.
pin code
Do not use more than 75% of the rated power and use reactive power if
possible.
Increase power generation (subject to limitations imposed by other
active DRMs).
Mode Conditions DRM0
Operate the disconnect device.
Model
Increase power consumption (subject to limitations imposed by other
active DRMs).
Operating instructions
a-TroniX inverter AX series, 1ph
7
3
8th
4
5
1
function
6
2
The DRM supports multiple demand response modes by issuing control signals as described below.
DRM2 Consume no more than 50% of rated power.
DRM7
DRM6 Generate no more than 50% of rated power.
DRM4
DRM1
DRM5 Do not produce power.
Currently only the DRM0 function is supported, other functions are under development.
DRM3
A NOTICE
DRM0 setting:
• DRM
DRM PIN definition:
DRM8
3
Operate the disconnect device.
DRM0
1
Emergency stop of the inverter.
2
ESTOP
4
Definition GND GND DRM0 +3.3V DRM4/8 DRM3/7 DRM2/6 DRM1/5
atx009de0823