background image

How to use

Figure 21

Figure 22

1.  Turn ON the water connection 

through the ball valve. (Figure 21)

1.  Turn ON the water connection 

through the ball valve. (Figure 22)

A. O. Smith

ON

3.  To dispense water from the storage 

tank, press the water dispense button 

once. To stop the water flow, press the 

water dispense button again.

(Figure 26)

Figure 25

3.  To dispense water from the storage 

tank, turn the faucet knob in 

anti-clockwise direction. (Figure 25)

Figure 23

2.  Switch ON the power supply and 

press the power button of the 

purifier. (Figure 23)

Figure 24

Figure 26

2.  Switch ON the power supply and press 

the power button of the purifier. 

(Figure 24)

Note:

   • 

Discard the first cycle of pure water, before you start using it for consumption.

   • 

Make sure to discard the water in the storage tank if you have not used the purifier for  

    

more than 2 days.

A. O. Smith

ON

18

Содержание X6

Страница 1: ...nday 9 a m to 6 p m For calls registered at A O Smith Call Centre before 4 p m only Available only in selected cities For more details please call our 1800 103 2468 1860 500 2468 or log on to www aosm...

Страница 2: ...mers all over the world trust A O Smith Products for their quality and workmanship Our customer centric approach manifests itself in many other ways too If you need any information or assistance with...

Страница 3: ...nstructions 04 Introduction 05 Product overview 07 Function of indicators 09 Water flow 11 Electrical diagram 13 Safety precautions 15 How to use 18 Draining drip tray 20 How to maintain your product...

Страница 4: ...TECHNOLOGY SCMT is an additional stage of purification to prevent any potential secondary microbial contamination post RO purification Double protection ensures purified and healthy water for model on...

Страница 5: ...of information LARGE STORAGE CAPACITY Purified water storage capacity of 9 litres AESTHETICS ColourMatch System to suit your kitchen d cor for model only WQA CERTIFIED RO MEMBRANE RO membrane element...

Страница 6: ...Smith representative immediately About this Manual This manual is a guide to good practice for operating and periodic maintenance of the A O Smith Water Purifier This does not contain the full servici...

Страница 7: ...nd its component parts for possible damage DO NOT install or attempt to repair any damaged component parts If you detect any damage in your A O Smith Water Purifier please contact the company through...

Страница 8: ...contaminants found today in the water supply which if consumed in excess can be detrimental to human health TDS Total Dissolved Solids like Nitrates Chlorides Sulphates etc Pesticides and VOC Volatile...

Страница 9: ...um minerals which helps to improve the taste and quality of water It adds the required essential minerals back to water and balances the pH of water Stage 6 Silver Activated Post Carbon Water is passe...

Страница 10: ...Drip Tray LED Display Panel Indicators Water Dispensing Nozzle Top Cover Main Body Water Level Indicator Faucet Knob Changeable Panel Drip Tray Cover Front View LED Display Panel Indicators Overflow...

Страница 11: ...Drip Tray LED Display Panel Indicators Water Dispense Nozzle Top Cover Main Body Water Level Indicator Water Dispense Button Changeable Panel Drip Tray Cover Back View Rear Cover Overflow water Reject...

Страница 12: ...o blink with continuous beep till it is fixed Note Call A O Smith Customer Care Centre if you notice continuous blinking of Tank full indicator This button is used to switch ON OFF the Water Purifier...

Страница 13: ...mer Care Centre to replace the Sediment filter and or Pre Carbon filter SCPA change indicator This indicates that the Sediment filter and or Pre Carbon filter needs to be replaced SCPA change indicato...

Страница 14: ...t Check Valve Low Pressure Switch Inlet Solenoid valve Flow Restrictor Flush Solenoid valve Waste water Pure water Faucet Overflow water Level 1 Sensor Level 2 Sensor Storage Tank MIN TECH Silver Acti...

Страница 15: ...nt filter Ball valve Inlet water 3 way joint Inlet Solenoid valve Flow Restrictor Flush Solenoid valve Waste water Pure water Silver Activated Post Carbon MIN TECH Check valve SCMT Dispensing Solenoid...

Страница 16: ...l Sensor Upper Level Sensor Reset PCB Driver Board SMPS 150V 300V 50 Hz 1 AC supply P N 24V DC GND Figure 8 Low Pressure Switch Pump Flush SV Inlet SV Water Leakage PCB Lower Level Sensor Upper Level...

Страница 17: ...re 9 Faucet SV Low Pressure Switch Pump Flush SV Inlet SV Water Leakage PCB Lower Level Sensor Upper Level Sensor Electronic Faucet PCB Reset PCB Driver Board SMPS 150V 300V 50 Hz 1 AC supply P N 24V...

Страница 18: ...these products are designed keeping highest safety standards in mind there are certain Do s and Dont s which need to be followed while using these products Do not move the product when product is runn...

Страница 19: ...must be done only by A O Smith Company Authorised Service Technician Figure 17 CAUTION Figure 15 Do not connect hot water to the product Figure 15 Heater CAUTION Figure 16 Do not use the purifier if...

Страница 20: ...igure 18 Do not put foreign objects or hand inside the purifier Caution is needed especially for children Figure 19 Note It is recommended not to switch off the Water Purifier and or turn off the wate...

Страница 21: ...e 26 Figure 25 3 To dispense water from the storage tank turn the faucet knob in anti clockwise direction Figure 25 Figure 23 2 Switch ON the power supply and press the power button of the purifier Fi...

Страница 22: ...the Cover Strip by pulling it out gently from the main body Figure 27 2 Attach the Drip Tray assembly into the main body through slots provided in the main body Figure 28 Figure 28 Attaching Drip Tray...

Страница 23: ...y by pulling it forward Figure 30 We have provided removable Drip Tray with the product In case there is slippage of water it gets collected in Drip Tray A O Smith Figure 31 2 Remove Drip Tray cover b...

Страница 24: ...e a soft dry cloth to clean the purifier Figure 35 Figure 37 Use A O Smith genuine accessories only for optimal performance of the purifier Figure 37 Figure 36 Replace filters regularly according to t...

Страница 25: ...pulling it out gently from the main body Figure 38 Figure 38 3 Remove the Changeable panel by pulling it out from the slot Figure 40 4 Insert the new Changeable panel and press gently to get it fixed...

Страница 26: ...entre Decreased flow of purified RO membrane filters may Call Customer Care Centre water All models be clogged or damaged for RO membrane filters replacement Less No reject water Check if the reject w...

Страница 27: ...the Water 10 times and SCPA triggered indicating that Purifier and call Customer change LED blinks the filters need to be Care Centre for continuously replaced and the water filters replacement All mo...

Страница 28: ...Pump type Diaphragm pump 24VDC 0 26 Amps Operating Pressure 125 psi Max Input voltage range 150 300 VAC 50 Hz Power rating Max 48 Watts for model only 60 Watts for model only Pressure Rating 7 psi to...

Страница 29: ...Dissolved Solids TDS Up to 2000 ppm Total hardness Up to 500 ppm Turbidity Up to 5 NTU Iron 0 3 ppm max Feed water pressure 7 psi to 30 psi Feed water temperature 5 C to 45 C Recommended input feed w...

Страница 30: ...As per the warranty the RO membrane needs to be replaced at 400 hrs approximately 6 000 litres purified water or 800 hrs approximately 12 000 litres purified water depending on the quality of the feed...

Страница 31: ...ter Sediment filter Pre Carbon filter RO membrane MIN TECH Mineraliser Technology Silver Activated Post Carbon and UV Chamber for model only SCMT Silver Charged Membrane Technology for model only 5 Wh...

Страница 32: ...ilters 15 Can A O Smith Water Purifier be mounted on the wall and can it be table top Yes A O Smith Water Purifier can be mounted on the wall or can be placed on the counter 16 What are changeable col...

Страница 33: ...defects occurring due to abuse faulty care maintenance repair or alteration to the product or to its parts by unauthorised personnel 6 The Company s liability under this warranty shall be limited to t...

Страница 34: ...beyond the control of A O Smith 13 The customer will have no claim under this warranty in respect of any personal injury sickness illness death property damage or consequential damages arised either...

Страница 35: ...residential and self consumption purpose d Product shall be in regular use and maintained as per product manual guidelines e Product feed water quality is as per the recommendations Refer point 17 f...

Страница 36: ...ods to and from the Authorised Service Provider shall be borne by the customer directly 4 If during such service it is necessary for the Company or Authorised Service Provider to replace or repair def...

Страница 37: ..._____________ Phone ________________________ Mobile ________________________ E mail ________________________ Dealer s Stamp and Signature Invoice Number ______________________________ Dated __________...

Страница 38: ...cs aosmithindia com Registered Office A O Smith India Water Products Private Limited formerly known as A O Smith India Water Heating Private Limited Plot No 300 Phase 2 KIADB Industrial Area Harohalli...

Страница 39: ...103 2468 1860 500 2468 2 Calls registered with A O Smith Customer Care Centre on working days before 4 pm 3 Within city municipal limits only 4 Restricted to service requests only 5 Service may differ...

Страница 40: ...enters the bicycle industry 1889 Water heater division introduces the first glass lined commercial water heater the A O Smith Burkay B 65 1954 A O Smith was a leading supplier of line pipe 1927 State...

Отзывы: