is
Instruction manual SGE
87
S15 (blocking error)
Short circuit from
dummy 2
Short circuit in sensor
circuit
Replace the dummy sensor
(2)
To replace the necessary parts, you must contact your installation
engineer
S17 (blocking error)
Short circuit from
temperature sensor S
2
at the bottom of the
tank.
Short circuit in sensor
circuit
Replace the cable and/or sensor.
To replace the necessary parts, you must contact your installation
engineer
S18 (blocking error)
Short circuit from
temperature sensor S
1
in the collector.
Short circuit in sensor
circuit
Replace the cable and/or sensor.
To replace the necessary parts, you must contact your installation
engineer
F01 (blocking error)
Defect in power supply
circuit
Live and neutral
connected wrong way
around.
Be sure to connect the live and neutral correctly (3.11 "Electrically
connecting the water heater"); the water heater is phase-sensitive
See the electrical diagram (17 "Appendices").
Condensation on the
flame probe
1. Disconnect the lead at the flame probe
2. Ignite the water heater three times, with an interrupted
ionisation circuit
3. Reconnect the ionisation lead to the flame probe
4. Ignite the water heater again
5. The repeated ignition attempts will have caused the
condensation to evaporate
If errors persist, contact your installation engineer
Floating neutral
Install an isolating transformer (3.11.4 "Isolating transformer")
Contact your installation engineer to have an isolating transformer
installed
F02 (lock out error)
Fan fails to run at
correct speed.
Defective motor and/or
rotor.
1. Check the motor and rotor
2. Replace the fan if the motor or rotor is defective.
3. Reset controller
See the electrical diagram (17 "Appendices").
To have the wiring replaced and a new fan fitted, you must contact
your installation engineer
Code + description
Cause
Measure
Remark
Содержание SGE - 40
Страница 7: ...4 Instruction manual SGE gis ...
Страница 11: ...Contents 8 Instruction manual SGE ...
Страница 33: ...Installation 30 Instruction manual SGE 3 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33 ...
Страница 51: ...Conversion to a different gas category 48 Instruction manual SGE 4 is ...
Страница 59: ...Draining 56 Instruction manual SGE 6 gis ...
Страница 65: ...Status of the water heater 62 Instruction manual SGE 8 gis ...
Страница 69: ...Shutting down 66 Instruction manual SGE 10 gis ...
Страница 83: ...Instruction manual SGE 80 is ...
Страница 99: ...is Instruction manual SGE 96 ...
Страница 101: ...Service interval 98 Instruction manual SGE 14 is ...
Страница 110: ...Instruction manual SGE 107 is ...
Страница 115: ...Appendices 112 Instruction manual SGE 17 is 17 5 Declaration of conformity Declaration of conformity ...
Страница 117: ...Instruction manual SGE 114 ...