![A.O. Smith SGE - 40 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/a-o-smith/sge-40/sge-40_installation-user-and-service-manual_2837841003.webp)
E1
Errata
The amendments below apply to:
the preparation of the electrical connection of the solar heating control (3.12.1 "Preparation");
finishing maintenance (15.6 "Finalizing maintenance");
the electrical diagram of the solar heating control (17.4 "Electrical diagram solar heating system").
These instructions supersede the previous instructions of the solar heating control.
3.12.1
Preparation
Remove the cover (snap-on type) from the terminal block of the solar heating control.
This has the following terminals:
Power
n.a. n.a.
not applicable
Pump (solar)
not applicable
not applicable
L
N
-
-
-
-
-
-
L
3
N
L
4
-
-
-
-
-
-
-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
n
o
t
a
p
p
lic
a
b
le
S
e
n
s
o
r
S
1
n
o
t
a
p
p
lic
a
b
le
S
e
n
s
o
r
S
1
n
o
t
a
p
p
lic
a
b
le
S
e
n
s
o
r
S
2
n
o
t
a
p
p
lic
a
b
le
S
e
n
s
o
r
S
2
n
o
t
a
p
p
lic
a
b
le
n
o
t
a
p
p
lic
a
b
le
n
o
t
a
p
p
lic
a
b
le
n
o
t
a
p
p
lic
a
b
le
P
o
w
e
r
5V
S
e
n
s
o
r
S
4
Flow
s
ign
a
l
n
o
t
a
p
p
lic
a
b
le
n
o
t
a
p
p
lic
a
b
le
B
U
S
-li
n
k
B
U
S
-li
n
k
J13
J14
J3
J12
J15
J16
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
1
2
15.6 Finalizing
maintenance
To finalize the maintenance, carry out the following steps:
1. Fill the water heater (5 "Filling").
2. Start the water heater (9 "Starting the water heater").
3. Check the CO
2
value (3.12.3 "CO
2
adjustment").
4. Check the switching pressure of the pressure switch. (3.12.4 "Switching pressure
measurement")
5. Erase the message SERVICE REQUIRED. The displayed message can be reset in
either of two ways.
1. Temporary reset:
To postpone the message, press RESET once. The message will reappear on the
display 7 days later.
2.Full reset:
To fully reset the message, press and hold both RESET and ENTER at the same
time for 5 sec.
On completion of the full reset of the message, the message below will appear on the
display. This message will NOT be shown after a temporary rest of the message.
Содержание SGE - 40
Страница 7: ...4 Instruction manual SGE gis ...
Страница 11: ...Contents 8 Instruction manual SGE ...
Страница 33: ...Installation 30 Instruction manual SGE 3 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33 ...
Страница 51: ...Conversion to a different gas category 48 Instruction manual SGE 4 is ...
Страница 59: ...Draining 56 Instruction manual SGE 6 gis ...
Страница 65: ...Status of the water heater 62 Instruction manual SGE 8 gis ...
Страница 69: ...Shutting down 66 Instruction manual SGE 10 gis ...
Страница 83: ...Instruction manual SGE 80 is ...
Страница 99: ...is Instruction manual SGE 96 ...
Страница 101: ...Service interval 98 Instruction manual SGE 14 is ...
Страница 110: ...Instruction manual SGE 107 is ...
Страница 115: ...Appendices 112 Instruction manual SGE 17 is 17 5 Declaration of conformity Declaration of conformity ...
Страница 117: ...Instruction manual SGE 114 ...