![A.O. Smith SGE - 40 Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/a-o-smith/sge-40/sge-40_installation-user-and-service-manual_2837841103.webp)
Performing maintenance
100
Instruction manual SGE
15
s
6. Switch the controller
ON
by setting the ON/OFF switch to
position I
.
The display will now show
INTERNAL CHECK
for about 10 seconds, and
will then go to the main menu.
7. Activate "ON mode" by going through the following steps:
-
Press once on the blue arrow ( ) to position the cursor beside
ON
,
then press
.
-
Confirm the selection
START OPERATION
with
.
8. If there is no heat demand, then raise (11.4 "Setting the water temperature")
T
set
. Note the original setting. Draw some hot water off to create heat
demand.
9. Check whether the heating cycle runs correctly (9.3 "The appliance's
heating cycle").
10. If you have adjusted T
set
, return it to the original value (11.4 "Setting the
water temperature").
11. Remove the plastic cover on the top of the appliance.
12. Check the supply and burner pressures (3.13 "Check the supply pressure,
gas control valve pressure, CO
2
value and switching pressure") and adjust
them where necessary.
13. Check that all components of the chimney flue system are properly attached.
14. Check the pressure differential across the pressure
switch (3.13.4 "Switching pressure measurement") and, if this is too low, the
heat exchanger should be cleaned (15.4.3 "Clean heat exchanger").
15. Test the operation of the overflow valve of the protected cold supply setup.
The water should spurt out.
16. Check the drainage pipes from the discharge points of all valves and remove
any scale deposits that may be present.
17. Drain the water heater (see draining (6 "Draining")).
15.3 Water-side
maintenance
15.3.1
Introduction
The following steps must be carried out on the water side:
1. Descaling and cleaning the tank
.
2. Clean condensation water discharge.
15.3.2
Descaling and cleaning the tank
Scale and lime build-up prevent effective conduction of the heat to the water.
Periodic cleaning and descaling prevents build-up of these deposits. This
increases the service life of the water heater, and also improves the heating
process.
INTERNAL CHECK
MENU
»OFF
^ ON
È WEEK PROGRAM
Содержание SGE - 40
Страница 7: ...4 Instruction manual SGE gis ...
Страница 11: ...Contents 8 Instruction manual SGE ...
Страница 33: ...Installation 30 Instruction manual SGE 3 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33 ...
Страница 51: ...Conversion to a different gas category 48 Instruction manual SGE 4 is ...
Страница 59: ...Draining 56 Instruction manual SGE 6 gis ...
Страница 65: ...Status of the water heater 62 Instruction manual SGE 8 gis ...
Страница 69: ...Shutting down 66 Instruction manual SGE 10 gis ...
Страница 83: ...Instruction manual SGE 80 is ...
Страница 99: ...is Instruction manual SGE 96 ...
Страница 101: ...Service interval 98 Instruction manual SGE 14 is ...
Страница 110: ...Instruction manual SGE 107 is ...
Страница 115: ...Appendices 112 Instruction manual SGE 17 is 17 5 Declaration of conformity Declaration of conformity ...
Страница 117: ...Instruction manual SGE 114 ...