![A.O. Smith SGE - 40 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/a-o-smith/sge-40/sge-40_installation-user-and-service-manual_2837841034.webp)
Instruction manual SGE
31
is
Explanation of types of installation
Note
Make sure that the chimney flue discharges into an area approved for this
type of installation.
3.10.3
Concentric connections
The table shows the requirements for concentric systems.
Warning
Install flue gas discharge pipe runs with a run-off of 5 mm per metre towards
the water heater.
Flue gas discharge requirements for concentric systems (C13, C33)
Caution
Both conditions stated in the table must be fulfilled.
Even if you use less than the stated maximum number of bends, the maximum
pipe length
still
may not be exceeded.
Even if you use less than the stated maximum pipe length, the maximum
number of bends
still
may not be exceeded.
The following example illustrates how to use the table.
Practical example of concentric flue gas discharge
Example
The figure shows a SGE 60 installation. The water heater must be fitted with 10
m of concentric pipe (C13/C33) and four 90 degree bends. The configuration
must be checked for compliance with the requirements stated in the table.
Installation type
Description
B23
Air for combustion is drawn from the boiler room.
C13
Concentric and/or parallel wall flue terminal.
C33
Concentric and / or parallel roof flue terminal
C43
Water heaters on common air supply and flue gas discharge (concentric
and/or parallel) in multi-storey building.
C53
Air supply and flue gas discharge terminal types mixed.
C63
Water heaters supplied without flue gas discharge materials and/or terminal.
These water heaters must be installed in compliance with local regulations.
Appliance
Diameter
Maximum length Maximum
number of 90
o
bends
SGE 40
100/150 mm
40 m
7
SGE 60
100/150 mm
40 m
7
Содержание SGE - 40
Страница 7: ...4 Instruction manual SGE gis ...
Страница 11: ...Contents 8 Instruction manual SGE ...
Страница 33: ...Installation 30 Instruction manual SGE 3 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33 ...
Страница 51: ...Conversion to a different gas category 48 Instruction manual SGE 4 is ...
Страница 59: ...Draining 56 Instruction manual SGE 6 gis ...
Страница 65: ...Status of the water heater 62 Instruction manual SGE 8 gis ...
Страница 69: ...Shutting down 66 Instruction manual SGE 10 gis ...
Страница 83: ...Instruction manual SGE 80 is ...
Страница 99: ...is Instruction manual SGE 96 ...
Страница 101: ...Service interval 98 Instruction manual SGE 14 is ...
Страница 110: ...Instruction manual SGE 107 is ...
Страница 115: ...Appendices 112 Instruction manual SGE 17 is 17 5 Declaration of conformity Declaration of conformity ...
Страница 117: ...Instruction manual SGE 114 ...