background image

23

TABLE 6 - COPPER SHEATH ELEMENT AND WATTAGE CHART

K.W.

ELEMENT 

WATTAGE

120V

208V

240V

277V

480V

PART NO.

PART NO.

PART NO.

PART NO.

PART NO.

1.0

1000W

- - -

9002863115

90001431005

- - -

- - -

1.5

1500W

9002963005

9000145005

9002864005

9001225115

- - -

2.0

2000W

9003947005

9002858005

9000145005

9004709115

- - -

2.5

2500W

9002859005

9004712105

9002860005

9002890005

9002861005

3.0

3000W

9002862005

9002868005

9003959005

9003958005

9003961005

3.5

3500W

- - -

9003950005

9004712105

- - -

- - -

MAX 3.5KW INPUT FOR 6 GALLON UNITS, ELEMENTS BELOW DOTTED LINE CANNOT BE USED ON 6 GALLON UNITS

4.0

4000W

- - -

9002867005

9002868005

9001229005

9002869005

4.5

4500W

- - -

9003952005

9003950100

9003960005

9001225005

5.0

5000W

- - -

9001224005

9003957005

9001231005

9001236005

5.5

5500W

- - -

9002871005

9002867005

- - -

9002872005

6.0

6000W

- - -

9003953005

9003952005

9002874005

9002875005

TABLE 7 - INCOLOY SHEATH ELEMENT AND WATTAGE CHART

K.W.

ELEMENT 

WATTAGE

120 V

208 V

240 V

277 V

480 V

PART NO.

PART NO.

PART NO.

PART NO.

PART NO.

1.5

1500 W

9004279005

9004283005

9004290005

9004736105

Not Available

2.0

2000 W

9004280005

9004284005

9004283005

9004290005

9004298005

2.5

2500 W

9004281005

9004285005

9004291005

9004295005

9004299005

INCOLOY ELEMENTS BELOW THIS LINE CANNOT BE USED ON 6 GALLON UNITS BECAUSE OF ELEMENT LENGTH

3.0

3000 W

9004282005

9004751115

9000664005

9004296005

9004300005

3.5

3500 W

Not Available

9003210005

9004292005

Not Available

Not Available

4.0

4000 W

Not Available

9004294005

9004751115

9000664005

Not Available

4.5

4500 W

Not Available

9004287005

9003210005

9004297005

9004301005

5.0

5000 W

Not Available

9004753105

9004293005

Not Available

Not Available

5.5

5500 W

Not Available

9004288005

9004294005

Not Available

Not Available

6.0

6000 W

Not Available

9004289005

9004287005

Not Available

Not Available

FIGURE 13 

Содержание Lowboy 6

Страница 1: ...FUTURE REFERENCE COMMERCIAL LIGHT DUTY ELECTRIC WATER HEATERS Thank you for buying this energy efficient water heater We appreciate your confidence in our products Lowboy 6 10 15 20 Models Series 102...

Страница 2: ...ition to electrical testing skills when performing service ANSI Z223 1 2006 Sec 3 3 83 Qualified Agency Any individual firm corporation or company that either in person or through a representative is...

Страница 3: ...ment grounding terminal or lead on the water heater HYDROGEN GAS FLAMMABLE Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long period of time gen...

Страница 4: ...rical Code CSA C22 1 The National Electrical Code may be ordered from National Fire Protection Association 1 Batterymarch Park Quincy MA 02269 The Canadian Electrical Code is available from the Canadi...

Страница 5: ...53 138 128 115 110 5000 5000 GPH 113 101 75 68 56 51 45 41 38 34 32 10 LPH 426 384 284 256 213 192 170 153 142 128 122 6000 6000 GPH 135 122 90 81 68 61 54 49 45 41 39 12 LPH 511 460 341 307 256 230 2...

Страница 6: ...6 APPROVALS MODEL AND RATING Lowboy 30 40 50 Tall 30 40 52 66 80 120 Lowboy 6 10 15 20 All models are listed by Underwriters Laboratories Inc...

Страница 7: ...ION INSTALL IN ACCORDANCE WITH ALL LOCAL CODES INSTALL VACUUM RELIEF IN COLD WATER INLET LINE AS REQUIRED BY LOCAL CODES INSTALL SUITABLE DRAIN PANS UNDER WATER HEATERS TO PREVENT DAMAGE DUE TO LEAKAG...

Страница 8: ...metimes installed in locations where leakage may result in property damage even with the use of a drain pan piped to a drain However unanticipated damage can be reduced or prevented by a leak detector...

Страница 9: ...imum of 120 degree F Consult a qualified installer or service agency Follow all manufacturer s Instructions for installation of these valves Before changing the factory setting on the thermostat read...

Страница 10: ...ated at an adequate drain inside the building Shall not have any valve or other obstruction between the relief valve and the drain The temperature pressure relief valve must be manually operated at le...

Страница 11: ...on J terminal to L1 It is then possible for both elements to operate at once as determined by the thermostats Regardless of element connection the heater operates in an unbalanced fashion The heater...

Страница 12: ...12 Figure 3 WIRING DIAGRAMS C 2 CIRCUIT FOR Lowboy 6 10 15 20 HEATERS EQUIPPED WITH HIGH LIMIT CONTROL A 8 CIRCUIT FOR DUAL ELEMENT HEATER FACTORY WIRED FIELD WIRING WHITE FOR 120V 277V...

Страница 13: ...lso check connections on top and or sides of heater Repair water leaks and tighten electrical connections as necessary 3 Depress the red manual reset button on each Thermostat ECO combination control...

Страница 14: ...MED and HI See Figure 5 The approximate equivalent temperatures for these three settings are LO 140 F 60 C MED 160 F 71 C and HI 181 F 83 C These thermostats are set from the factory at the LO 140 F 6...

Страница 15: ...y the anode rod This does not affect water s taste or color The rod must be maintained to keep tank in operating condition Anode deterioration depends on water conductivity not necessarily water condi...

Страница 16: ...le accumulations on the elements causes sizzling and hissing noises when the heater is operating The sounds are normal however the tank bottom and elements should be cleaned See the Maintenance sectio...

Страница 17: ...ary to shut off electricity and drain tank to perform procedure Water leaks at the elements may be due to 1 Defective element which leaks at terminals or thru flange Replace element 2 Loose element ga...

Страница 18: ...d by improper gas supply line sizing gas type venting connections combustion air voltage wiring or fusing Failure to follow applicable codes Failure to follow printed instructions Abuse misuse acciden...

Страница 19: ...19 NOTES...

Страница 20: ...r parts will be shipped at prevailing prices and you will be billed accordingly The model number of your Water Heater will be found on the rating plated located above the lower access panel Be sure to...

Страница 21: ...3307 000 043307 000 043307 000 7 Personnel Protector 9003914015 9003914015 9003914015 9003914015 8 Pipe Nipple 194130 194130 3 194130 3 194130 3 9 Plate Knockout 43293 1 43293 1 43293 1 43293 1 PLUG 1...

Страница 22: ...57015 9002857015 9002857015 9002857015 9002857015 9002857015 9002857015 7 Thermostat Bracket each 9003898215 9003898215 9003898215 9003898215 9003898215 9003898215 9003898215 9003898215 9003898215 8 P...

Страница 23: ...9002874005 9002875005 TABLE 7 INCOLOY SHEATH ELEMENT AND WATTAGE CHART K W ELEMENT WATTAGE 120 V 208 V 240 V 277 V 480 V PART NO PART NO PART NO PART NO PART NO 1 5 1500 W 9004279005 9004283005 900429...

Страница 24: ...24...

Отзывы: