background image

 

 

 

 

Product Features 

Energy-saving Heating 

A new generation water heater, heating residential water by air-source   
based on the Inverse Cano Principle.   

MAX

 

 

MAX function means more hot water output, therefore, better bath   
experience. 

AES (adaptive energy-saving system) 

By recording and learning user’s habit of water usage, patented AES   
feature adopts heating cycles automatically, which will facilitate water   
usage and save energy by minimizing thermal loss.   

Hot Water Amount Display 

Five light blocks visibly indicate the hot water amount available in tank. 

Circulating pump 

 

The cold water section can be removed by pump circulation (sold separately) to ensure hot water at all time. 

Power-off memory 

By power-on more than 4 hours, the water heater could keep setting information for 72 hours when power 

supply is cut-off. 

Intelligent defrosting

   

The automatic intelligent defrost function can solve the problems effectively such as freezing of exchanger, 

frost remaining etc., and ensure the system to be operated efficiently and stably. 

Intelligent dormancy 

If no operation is performed within 3 minutes, the water heater enters into a dormant state. 

The unit will enter sleep state with no operation within three minutes.

 

Wired remote controller 

The controller and the unit are to be installed separately for clear sight and convenient operation. 

Glass-lined special protective tank 

The Glass-lined protection tank is a patent by A.O.Smith, coating tank with Silicide smoothly and fusion at 

870

. The anti

-rust and anti-scaling glass coating has pass 100,000 cycles fatigue life test in accordance 

with relevant UL Standards.   

Anode rod protection 

A powerful steel-core-anode rod is used to protect tank and greatly prolong service life of the heat pump 

water heater. 

High Efficiency Energy-saving Insulation 

A polyurethane foam insulating layer without Freon reduces heat loss effectively.

 

 

 

 

 

 

 

 

 

 

 

Figure 3

EFFICIENCY

1

2

SETTING

PROGRAM

INSTANT

MODE

PUMP

HYBRID TURBO

P U M P

Содержание HPI-40C1.0AT

Страница 1: ...Heat Pump Water Heater HPI 40 50C1 0AT User Guide HPI 40 50C1 0AE...

Страница 2: ...as gained respect and support of homeowners contractors architects and specifying engineers in over 60 countries by providing innova tive energy saving products designed for years of trouble free serv...

Страница 3: ...Energy saving Heating 4 MAX 4 AES adaptive energy saving system 4 Circulating pump 4 Power off memory 4 Intelligent defrosting 4 Intelligent dormancy 4 Wired remote controller 4 Glass lined special p...

Страница 4: ...t once stop the operation contact local authorized dealer and carry out inspection or repair by our company recommended professional installers z In case of any component soaked by water the water hea...

Страница 5: ...ble 2 Specifications Model Rated volume L Voltage V Frequency Hz Rated input power W Rated current A Setting temperature range C Noise level dB A Rated pressure MPa Maximum power of quick heating W Ma...

Страница 6: ...nt High water temperature protection The system will shut down all loads to ensure safety in case any of the multiple sensors inside the water heater reaches 90 C High Temperature Limit Protection Swi...

Страница 7: ...ion can solve the problems effectively such as freezing of exchanger frost remaining etc and ensure the system to be operated efficiently and stably Intelligent dormancy If no operation is performed w...

Страница 8: ...touch the floor directly and there should be a raised bottom at around 20mm under the tank Please make sure the tank is loaded steadily z The tank of the water heater shall be installed near to the po...

Страница 9: ...lid of control box with tightened screw Finally fix the whole control box on the 86 box which is preinstalled on the wall Power Connection z All the wires must come with water heater and be installed...

Страница 10: ...button the heater will be power on Setting temp and actual temp will be displayed a few seconds later Figure 8 When heater is power on pressing Power ON OFF button turn the heater into power off stat...

Страница 11: ...ess the key once to display the time Figure 9 for 16 seconds and then to return to original state Timer Setting With the indicator TIMER 1 lighted up long press and hold button to enter TIMER1 startin...

Страница 12: ...GRAM INSTANT MODE PUMP SETTING PROGRAM INSTANT MODE PUMP Neither TIMER 1 nor TIMER 2 could work simultaneously with AES that means once TIMER 1 or TIMER 2 turns on AES will turn off automatically Pres...

Страница 13: ...TANT simultaneously for 8 seconds will turn off the heater after 2 seconds display off all characters on screen and reset setting temp clock timer to default status and remove AES memory and faulty co...

Страница 14: ...lve open drain valve rotate the handle on the temperature and pressure relive valve then drain water through discharge pipe z Clean the tank regularly 1 Cut off the power and empty the tank 2 Connect...

Страница 15: ...ed dealer Display E6 Red wiring with eight core terminal short circuit or open circuit Contact local authorized dealer Display E8 Abnormal anode bar wiring Contact local authorized dealer Display H6 G...

Страница 16: ...13 Wiring diagram Figure 16 Electrical wiring diagram 1 3 1...

Страница 17: ...water discharge through temperature and pressure safty valve as it may have risk to cause scald z For indoor installation it is normal that the air outlet grill may have a little condensate water if t...

Страница 18: ...A O SMITH WATER HEATER CO LTD A O Smith reserves the right to make product changes or improvements at any time without notice 500444 022 Rev 00...

Отзывы: