A.O. Smith HPI-40C1.0AT Скачать руководство пользователя страница 4

 

 

User Guide 

Please read this instruction carefully before installation and operation of the water heater and keep this 

instruction well for further reference.   

z

 

Only professional installers acknowledged by A.O.SMITH are permitted to install the heat pump water 

heater. If the water heater is installed with self-prepared installation materials or by un-authorized 

personnel, A.O.SMITH will not be responsible for all losses incurred thereby, including but not limited 

to pipeline leakage, fall or improper installation that may affect normal operation and performance of 

water heater.   

z

 

The heat pump water heater is for residential application. Therefore, it may affect life expectation if it is 

used for commercial application.

 

 

z

 

After installation and operation of the heat pump water heater, users should inspect the system regularly 

and make necessary maintenance according to operation conditions. If any abnormality occurs, please 

stop operation immediately, and contact local authorized dealer for repair to ensure the normal, safe, and 

reliable operation of the water heater.

 

 

z

 

The anode rod is a consumable part and it is generally suggested to check and replace the anode rod 

every 2 or 3 years. Users could contact the local authorized dealer for check and replacement to extend 

life expectation of water heater. 

z

 

Prior to any maintenance or repair of the heat pump water heater, please cut off power supply. 

Unauthorized personnel are not permitted to adjust and repair the heater.

 

z

 

In case the water heater is subject to dry heating, the generated steam or burning water might lead to 

serious scald. Therefore, it is necessary to fill the water heater with water. If dry heating occurs, cut off 

the power and water supply at once, stop the operation, contact local authorized dealer, and carry out 

inspection or repair by our company recommended professional installers.   

z

 

In case of any component soaked by water, the water heater is not permitted to use until checked by 

authorized service staff.   

z

 

Main components of the storage electrical heater are protected by insulation material to ensure safety use. 

Any damaged power cords should be replaced by authorized service staff.   

z

 

The pressure relief valve, equipped on the heat pump water heater, is forbidden to change installation 

position or be blocked. Discharge pipe is required to connect the valve and down toward floor drain. 

z

 

Water, including hot water, out of the heat pump water heater is not permitted for drinking.   

z

 

Electricity for the heat pump water heater should be supplied by independent branch of circuit, of which 

electricity meter, breaker, maximum current need to be checked by professional electrician in advance.   

z

 

Power socket should be located at a dry place, and power cord should not be pu shed or pulled with wet 

 hand  to avoid the danger of electric shock. 

z

 

Damaged electric wire, aged, loose and unfixed socket are not suggested to be used because of the 

danger of electric shock, short circuits, fires, etc. Please ensure power cord and socket could be 

connected well. 

z

 

A. O. SMITH water Heater Company Ltd reserves the rights to explain all provisions mentioned above.   

CAUTION: 

Failure to follow instructions in the user guide may cause fire disaster, which would be a threat 

to life and property security.

 

 

 

WARNING:

 Heat pump water heater is not permitted for use without reliable ground wire circuit for power 

socket. In case of indicator lighted up for “ground wire circuit fault”, please immediately stop 

using, pull plug and contact local authorized dealer. Well-drained floor drain is essential to 

prevent the damage to surroundings or downstairs in case of leakage of heater or joint.   

Содержание HPI-40C1.0AT

Страница 1: ...Heat Pump Water Heater HPI 40 50C1 0AT User Guide HPI 40 50C1 0AE...

Страница 2: ...as gained respect and support of homeowners contractors architects and specifying engineers in over 60 countries by providing innova tive energy saving products designed for years of trouble free serv...

Страница 3: ...Energy saving Heating 4 MAX 4 AES adaptive energy saving system 4 Circulating pump 4 Power off memory 4 Intelligent defrosting 4 Intelligent dormancy 4 Wired remote controller 4 Glass lined special p...

Страница 4: ...t once stop the operation contact local authorized dealer and carry out inspection or repair by our company recommended professional installers z In case of any component soaked by water the water hea...

Страница 5: ...ble 2 Specifications Model Rated volume L Voltage V Frequency Hz Rated input power W Rated current A Setting temperature range C Noise level dB A Rated pressure MPa Maximum power of quick heating W Ma...

Страница 6: ...nt High water temperature protection The system will shut down all loads to ensure safety in case any of the multiple sensors inside the water heater reaches 90 C High Temperature Limit Protection Swi...

Страница 7: ...ion can solve the problems effectively such as freezing of exchanger frost remaining etc and ensure the system to be operated efficiently and stably Intelligent dormancy If no operation is performed w...

Страница 8: ...touch the floor directly and there should be a raised bottom at around 20mm under the tank Please make sure the tank is loaded steadily z The tank of the water heater shall be installed near to the po...

Страница 9: ...lid of control box with tightened screw Finally fix the whole control box on the 86 box which is preinstalled on the wall Power Connection z All the wires must come with water heater and be installed...

Страница 10: ...button the heater will be power on Setting temp and actual temp will be displayed a few seconds later Figure 8 When heater is power on pressing Power ON OFF button turn the heater into power off stat...

Страница 11: ...ess the key once to display the time Figure 9 for 16 seconds and then to return to original state Timer Setting With the indicator TIMER 1 lighted up long press and hold button to enter TIMER1 startin...

Страница 12: ...GRAM INSTANT MODE PUMP SETTING PROGRAM INSTANT MODE PUMP Neither TIMER 1 nor TIMER 2 could work simultaneously with AES that means once TIMER 1 or TIMER 2 turns on AES will turn off automatically Pres...

Страница 13: ...TANT simultaneously for 8 seconds will turn off the heater after 2 seconds display off all characters on screen and reset setting temp clock timer to default status and remove AES memory and faulty co...

Страница 14: ...lve open drain valve rotate the handle on the temperature and pressure relive valve then drain water through discharge pipe z Clean the tank regularly 1 Cut off the power and empty the tank 2 Connect...

Страница 15: ...ed dealer Display E6 Red wiring with eight core terminal short circuit or open circuit Contact local authorized dealer Display E8 Abnormal anode bar wiring Contact local authorized dealer Display H6 G...

Страница 16: ...13 Wiring diagram Figure 16 Electrical wiring diagram 1 3 1...

Страница 17: ...water discharge through temperature and pressure safty valve as it may have risk to cause scald z For indoor installation it is normal that the air outlet grill may have a little condensate water if t...

Страница 18: ...A O SMITH WATER HEATER CO LTD A O Smith reserves the right to make product changes or improvements at any time without notice 500444 022 Rev 00...

Отзывы: