Clock setting 

Long press the key“

” to enter clock setting state 

under non-timing state, the hour digit will flash; 

press the key “ ” or “

”to set the hour with a range 

of “0-23”, then press the key “

”, the minute digit 

will flash; press the key “ ” or “

”to set the minute 

with a range of “0-59”. If the key is hold, the data 

will change consecutively, then press the key“

”, 

the clock setting will be completed and exit the clock 

setting state. 

 
 
 
 
 
 
 
 
 
 
 

Figure 9  

 

Clock view

:  

Under the startup state, press the key “   

” once to   

display the time (Figure 9) for 16 seconds and then to 

return to original state. 

Long press the key“      ” to enter clock setting state under non-timing state, the hour digit will flash; press 

the key “ ” or “

”to set the hour with a range of “0-23”, then press the key “     

”, the minute digit will 

flash; press the key “ ” or “

”to set the minute with a range of “0-59”. If the key is hold, the data will 

change consecutively, then press the key“      ”, the clock setting will be completed and exit the clock 
setting state. 

Clock view

: under the startup state, press the key “     

” once to display the time (Figure 9) for 16 seconds 

and then to return to original state.   

Timer Setting 

With the indicator TIMER 1 lighted up, long press and hold “         ” button to enter TIMER1 starting time 

setting state. “TIMER 1” “ON”, hour and minute digits will flash at the same time. Press “

” or “

” to 

increase or decrease the hour by 1 and the minute by 30.If the key “ ” or “

” is hold, the set digit will 

change consecutively. After finishing the start time setting, press “         ” button to enter TIMER 1 ending 

time setting state. “TIMER 1” “OFF”, hour and minute digits will flash at the same time. The stop time 

setting is same as above. Press“         ” button to confirm the “TIMER 1” setting. (Figure 10, 11) 

When the indicator light “TIMER 2” is on: the setting method is same as above. 

With indicator of both Timer-1 and Timer-2 light up, water heater will work in both periods. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 10  

Figure 11 

Figure 12 

 

 

 

PROGRAM

INSTANT

MODE

PUMP

1

PROGRAM

INSTANT

MODE

PUMP

1

PROGRAM

INSTANT

MODE

PUMP

SETTING

PROGRAM

INSTANT

MODE

PUMP

PROGRA

PROGRA

PROGRA

PROGRA

PROGRA

PROGRA

PROGRA

PROGRA

PROGRA

PROGRA

PROGRA

The heating timer interval can be set based on the personal water consumption need, i.e. the point to start or 

stop of the water heater. 

Содержание HPI-40C1.0AT

Страница 1: ...Heat Pump Water Heater HPI 40 50C1 0AT User Guide HPI 40 50C1 0AE...

Страница 2: ...as gained respect and support of homeowners contractors architects and specifying engineers in over 60 countries by providing innova tive energy saving products designed for years of trouble free serv...

Страница 3: ...Energy saving Heating 4 MAX 4 AES adaptive energy saving system 4 Circulating pump 4 Power off memory 4 Intelligent defrosting 4 Intelligent dormancy 4 Wired remote controller 4 Glass lined special p...

Страница 4: ...t once stop the operation contact local authorized dealer and carry out inspection or repair by our company recommended professional installers z In case of any component soaked by water the water hea...

Страница 5: ...ble 2 Specifications Model Rated volume L Voltage V Frequency Hz Rated input power W Rated current A Setting temperature range C Noise level dB A Rated pressure MPa Maximum power of quick heating W Ma...

Страница 6: ...nt High water temperature protection The system will shut down all loads to ensure safety in case any of the multiple sensors inside the water heater reaches 90 C High Temperature Limit Protection Swi...

Страница 7: ...ion can solve the problems effectively such as freezing of exchanger frost remaining etc and ensure the system to be operated efficiently and stably Intelligent dormancy If no operation is performed w...

Страница 8: ...touch the floor directly and there should be a raised bottom at around 20mm under the tank Please make sure the tank is loaded steadily z The tank of the water heater shall be installed near to the po...

Страница 9: ...lid of control box with tightened screw Finally fix the whole control box on the 86 box which is preinstalled on the wall Power Connection z All the wires must come with water heater and be installed...

Страница 10: ...button the heater will be power on Setting temp and actual temp will be displayed a few seconds later Figure 8 When heater is power on pressing Power ON OFF button turn the heater into power off stat...

Страница 11: ...ess the key once to display the time Figure 9 for 16 seconds and then to return to original state Timer Setting With the indicator TIMER 1 lighted up long press and hold button to enter TIMER1 startin...

Страница 12: ...GRAM INSTANT MODE PUMP SETTING PROGRAM INSTANT MODE PUMP Neither TIMER 1 nor TIMER 2 could work simultaneously with AES that means once TIMER 1 or TIMER 2 turns on AES will turn off automatically Pres...

Страница 13: ...TANT simultaneously for 8 seconds will turn off the heater after 2 seconds display off all characters on screen and reset setting temp clock timer to default status and remove AES memory and faulty co...

Страница 14: ...lve open drain valve rotate the handle on the temperature and pressure relive valve then drain water through discharge pipe z Clean the tank regularly 1 Cut off the power and empty the tank 2 Connect...

Страница 15: ...ed dealer Display E6 Red wiring with eight core terminal short circuit or open circuit Contact local authorized dealer Display E8 Abnormal anode bar wiring Contact local authorized dealer Display H6 G...

Страница 16: ...13 Wiring diagram Figure 16 Electrical wiring diagram 1 3 1...

Страница 17: ...water discharge through temperature and pressure safty valve as it may have risk to cause scald z For indoor installation it is normal that the air outlet grill may have a little condensate water if t...

Страница 18: ...A O SMITH WATER HEATER CO LTD A O Smith reserves the right to make product changes or improvements at any time without notice 500444 022 Rev 00...

Отзывы: