8
RHS
LHS
Fig. 5A Installation diagram
Fig. 5B Installation diagram
*Flexible Hoses to be procured by the customer, not part of standard product.
Note:
The product should be installed by applicable inlet outlet configuration only.
• Correct Installation is indicated by the A. O. Smith logo facing forward and in
horizontal condition.
• Refer Fig. 5A & Fig. 5B as applicable to the model to be installed.
• Please note that A. O. Smith Logo turned upside down or A. O. Smith logo facing
upwards indicate a wrong installation.
Fig. 5A Applicable for models EWSH PLUS - 15
and EWSH PLUS - 25
Fig. 5B Applicable for models EWSH PLUS 15 - LHS
and EWSH PLUS 25 - LHS
Lever
Safety Valve
To Drain
Blue Cap
Red Cap
Hot Water Tap
Cold Water Tap
Discharge Tube
*Flexible Hose
Lever
Safety Valve
To Drain
Blue Cap
Red Cap
Cold Water Tap
Hot Water Tap
Discharge Tube
*Flexible Hose