background image

43

warranty

A. O. Smith Corporation, the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater:

1.  THE TANK

 

If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable 

water  therein,  during the first THREE years after initial installation, the warrantor will supply a complete new A. O. Smith water heater of equivalent 

size and current model. Some government agencies are requiring energy efficient standards for water heaters. In the event regulations prohibit 

sale of a model of equivalent size and construction, A. O. Smith will provide a model which complies with the regulations of your area, in which 

case the consumer will be charged the difference in price between the like replacement and the energy efficient model required. The warranty on 

the replacement water heater will be limited to the unexpired term of the original warranty.

2.  ALL OTHER PARTS

 

If within ONE year after initial installation of this water heater, any part or portion shall prove upon examination by the warrantor to be defective in 

material or workmanship, the warrantor will repair or replace such part or portion at its option.

3.  CONDITIONS and EXCEPTIONS

 

This warranty shall apply only when the water heater is installed in accordance with local plumbing and building codes, ordinances and regulations, 

the printed instructions provided with it and good industry practices. In addition, a temperature and pressure relief valve, certified by A.G.A.and 

approved by the American Society of Mechanical Engineers, must have been installed.

 

a.  This warranty shall apply only when the heater is used:

 

 

(1) at temperatures not exceeding the maximum setting of its thermostat;

 

 

(2) at water pressure not exceeding the working pressure shown on the water heater;

 

 

(3) when filled with potable water, free to circulate at all times;

 

 

(4) in a noncorrosive and non-contaminated atmosphere;

 

 

(5) in the United States, its territories or possessions, and Canada.

 

 

(6) used with factory approved anode(s) installed;

 

 

(7) in its original installation location;

 

 

(8) sized in accordance with proper sizing techniques for commercial water heaters;

 

 

(9) bearing a rating plate which has not been altered, defaced or removed except as required by the warrantor;

 

 

(10) not used in a closed system without a properly sized and installed thermal expansion tank;

 

 

(11) fired at the proper voltage and wattage;

 

 

(12) maintained in accordance with the instructions printed in the manual included with the heater.

 

b.  Any accident to the water heater, any misuse, abuse (including freezing) or alteration of it, any operation of it in a modified  

 

 

 

form, or any attempt to repair tank leaks will void this warranty.

4.  SERVICE and REPAIR EXPENSE

 

Under this limited warranty the warrantor will provide only a replacement water heater or part thereof. The owner is responsible for all other costs. 

Such costs may include but are not limited to:

 

a.  Labor charges for service, removal, repair, or reinstallation of the water heater or any component part;

 

b.  Shipping, delivery, handling, and administrative charges for forwarding the new heater or replacement part from the nearest  

 

 

 

distributor and returning the claimed defective heater or part to such distributor;

 

c.   All cost necessary or incidental for any materials and/or permits required for installation of the replacement heater or part.

5.  LIMITATIONS ON IMPLIED WARRANTIES

 

Implied warranties, including any warranty of merchantability imposed on the sale of this heater under state law are limited to one (1) year duration for the 

heater or any of its parts. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

6.  CLAIM PROCEDURE

 

Any claim under this warranty should be initiated with the dealer who sold the heater, or with any other dealer handling the warrantor’s products. 

If this is not practicable, the owner should contact:

 

 

 

 

U.S. Customers 

 

 

 

Canadian Customers

 

 

 

 

A. O. Smith Water Products Company 

 

A. O. Smith Enterprises, Ltd.

 

 

 

 

500 Tennessee Waltz Parkway   

 

P. O. Box 310 - 768 Erie Street

 

 

 

 

Ashland City, TN  37015 

 

 

Stratford, Ontario N5A 6T3

 

 

 

 

Telephone: 1-800-323-2636 

 

 

Telephone: 1-800-265-8520

 

a.  The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or  

 

 

 

distributed by the warrantor.

 

b.  Dealer replacements are made subject to in-warranty validation by warrantor.

7.  DISCLAIMERS

 

NO  OTHER  EXPRESS  WARRANTY  HAS  BEEN  OR  WILL  BE  MADE  IN  BEHALF  OF  THE  WARRANTOR  WITH  RESPECT  TO  THE 

 

 

MERCHANTABILITY  OF  THE  HEATER  OR  THE  INSTALLATION,  OPERATION,  REPAIR,  OR  REPLACEMENT  OF  THE  HEATER.  THE 

 

 

WARRANTOR SHALL NOT BE RESPONSIBLE FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE

 

 

TO PERSONAL PROPERTY, OR OTHER CONSEQUENTIAL DAMAGE. THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS 

 

 

WARRANTY  OR  OTHERWISE  FOR  DAMAGE  TO  ANY  PERSONS  OR  PROPERTY,  WHETHER  DIRECT  OR  INDIRECT,  AND 

 

 

WHETHER ARISING IN CONTRACT OR IN TORT.

 

a.  Some states do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitation or    

 

 

 

exclusion may not apply to you.

 

b.  This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Fill in the following for your own reference. Keep it. Registration is not a condition of warranty. The model and serial number are found on the heater’s rating plate.
Model No.________________________________________ Serial No.________________________________ Date Installed ________________ 
Dealer’s Name_________________________________________________________________________________________________________ 
Dealer’s Address _______________________________________________________________________Phone No. _______________________
City and State __________________________________________________________________________Zip ____________________________

Содержание DURA-Power DRE-52

Страница 1: ...uture reference COMMERCIAL ELECTRIC WATER HEATERS Thank you for buying this energy efficient water heater We appreciate your confidence in our products MODELS DRE 52 80 120 SERIES 100 DVE 52 80 120 SE...

Страница 2: ...ing or replacement of gas piping or b the connection installation testing repair or servicing of appliances and equipment that is experienced in such work that is familiar with all precautions require...

Страница 3: ...ay also cause erratic control system operation on ELECTRONIC CONTROL models This water heater must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be...

Страница 4: ...ian StandardsAssociation 8501 East Pleasant Valley Road Cleveland OH 44131 3 If after reading this manual you have any questions or do not understand any portion of the instructions call the toll free...

Страница 5: ...ed to as Electronic Control models RECOVERY RATE IN GALLONS PER HOUR Temperature Rise F Standard KW Input BTU Hour 30 40 50 60 70 80 90 100 110 120 130 140 6 20 478 82 62 49 41 35 31 27 25 22 21 19 18...

Страница 6: ...6 APPROVALS MODEL AND RATING All models meet National Sanitation Foundation NSF 5 requirements All models are listed by Underwriters Laboratories Inc...

Страница 7: ...7 FEATURES AND COMPONENTS ELECTRONIC CONTROL MODELS FIGURE 1...

Страница 8: ...8 FEATURES AND COMPONENTS SURFACE MOUNT CONTROL MODELS FIGURE 2...

Страница 9: ...ank or connections will not result in damage to the area adjacent to the heater or to lower floors of the structure 3 Close to the point of major hot water usage and the power supply Hot water piping...

Страница 10: ...n to using the lowest possible temperature setting that satisfies your hot water needs a means such as a MIXING VALVE should be used at the hot water taps used by these people or at the water heater M...

Страница 11: ...relief valve must be manually operated at least once a year Caution should be taken to ensure that 1 no one is in front of or around the outlet of the temperature pressure relief valve discharge line...

Страница 12: ...tection and disconnect switch The water heater should be grounded in accordance with national and local codes Voltage applied to the heater should not vary more than 5 to 10 of the model and rating pl...

Страница 13: ...ace information display and element current sensors for monitoring the power circuits Refer to the control circuit label on the water heater for details The CCB ispoweredbyasmall120V 24Vtransformer Th...

Страница 14: ...14 CCB CENTRAL CONTROL BOARD CIRCUIT BOARD CONTROL CIRCUIT DIAGRAM ELECTRONIC CONTROL MODELS FIGURE 3 WIRING DIAGRAMS...

Страница 15: ...the heater circuits and includes wiring diagrams All heater circuits are designed for 60 50 hertz alternating current The water heater circuit wiring is 12 AWG AWM or TEW type rated 600 volts 105 C F...

Страница 16: ...to terminal L1 with black wires 3 Reconnect all yellow wires to terminal L2 with red wires 4 Connect incoming power to terminals L1 and L2 CONVERSION TO THREE PHASE When heater is shipped for connect...

Страница 17: ...page 8 The following describes the heater circuits and includes wiring diagrams All heater circuits are designed for 60 50 hertz alternating current The water heater circuit wiring is 12 AWG AWM or T...

Страница 18: ...ect all red wires to terminal L 2 with yellow wires 5 Connect incoming power to terminals L1 and L2 CONVERSION TO THREE PHASE When heater is shipped for connection to a single phase electrical service...

Страница 19: ...d electrical connections for tightness Also check connections on top and side of heater Repair water leaks and tighten electrical connections as necessary 3 Depress the red manual reset button on each...

Страница 20: ...when the water temperature reaches approximately 202 F 94 C When the ECO switch contacts open activate the electronic control system locks out and displays a Fault message Voltage to the contactor coi...

Страница 21: ...adjustable 1 to 20 differential set points for each bank First bank on is the last bank off Helps reduce operating costs during low moderate loads CONTROL SYSTEM NAVIGATION The UIM User Interface Modu...

Страница 22: ...control system has initiated heating operation Heating elements icon for a water heater equipped with 1 Bank of heating elements Each circle represents one heating element Each diagonal row of 3 elem...

Страница 23: ...played in this menu Economy Mode Setup Seven day 24 hour time clock with temperature set back capability to reduce operating costs during unoccupied or reduced demand periods Alarm Output Setup The co...

Страница 24: ...g This can improve the precision of temperature control in the storage tank and at points of use This feature can also be used to compensate for building recirculation loops hot water returning to the...

Страница 25: ...on off status of each Bank of heating elements Yes On No Off Alarm Condition Displays the status of the user definable Alarm Output function see Alarm Output Setup Menu Yes alarm condition has been m...

Страница 26: ...tional Buttons on the display changes as you navigate through the various menus and screens Use the Up Down buttons to select highlight in black the Economy Mode Setup menu from the Main Menu Press th...

Страница 27: ...ges to ACCEPT CANCEL when the adjustment mode is activated and how the current setting is outlined rather than highlighted in black Press the Operational Button underneath ACCEPT to enter and confirm...

Страница 28: ...Up Down and CHANGE buttons to enter the Mon sub menu Use the Up Down buttons to select highlight in black the Normal Operation Between setting Press the Operational Button underneath SELECT to change...

Страница 29: ...n current tank temperature drops below programmable Alarm SP Fault or Alert Used for external notification whenever a Fault or Alert condition is active Fault Used for notification whenever a Fault co...

Страница 30: ...sages in chronological order in this menu The most recent will be at the top of the list A time stamp is displayed below each listed Fault and Alert message showing when the Fault or Alert condition o...

Страница 31: ...the drain valve should be opened and the water allowed to run until it flows clean This will help to prevent sediment buildup in the tank bottom Periodically check the temperature and pressure relief...

Страница 32: ...lements should be examined regularly Lime scale accumulations may cause noises to occur during operation It is recommended that a heating element be removed periodically for examination If it is scale...

Страница 33: ...ed See the Maintenance section of this manual 2 Some of the electrical components of the water heater make sounds which are normal Contactors will click or snap as the heater starts and stops Transfor...

Страница 34: ...ters tank insert Q tip or similar absorbent material between jacket opening and valve to swab spud area Remove valve if leak is indicated and repair with pipe joint compound Water on the side of the t...

Страница 35: ...35 PIPING DIAGRAMS ONE TEMPERATURE WITH CIRCULATING LOOP INSERT B VACUUM RELIEF VALVE INSTALL PER LOCAL CODES PIPE TO OPEN DRAIN INSTALL IN ACCORDANCE WITH ALL LOCAL CODES...

Страница 36: ...36 PIPING DIAGRAMS INSERT B VACUUM RELIEF VALVE INSTALL PER LOCAL CODES...

Страница 37: ...37 PIPING DIAGRAMS INSERT B VACUUM RELIEF VALVE INSTALL PER LOCAL CODES...

Страница 38: ...OCAL CODES ONE TEMPERATURE ONE HEATER VERTICAL STORAGE TANK FORCED CIRCULATION WITHOUT BUILDING RECIRCULATION TWO TEMPERATURE WITH MIXING VALVE AND CIRCULATING LOOP TWO TEMPERATURE WITH MIXING VALVE P...

Страница 39: ...39 PIPING DIAGRAMS TWO HEATERS WITH HORIZONTAL STORAGE TANK WITH OR WITHOUT BUILDING RECIRCULATION INSERT B VACUUM RELIEF VALVE INSTALL PER LOCAL CODES...

Страница 40: ...S THREE HEATERS WITH HORIZONTAL STORAGE TANK WITH OR WITHOUT BUILDING RECIRCULATION THREE HEATERS WITH VERTICAL STORAGE TANK WITH OR WITHOUT BUILDING RECIRCULATION INSERT B VACUUM RELIEF VALVE INSTALL...

Страница 41: ...MS FOUR HEATERS WITH VERTICAL STORAGE TANK WITH OR WITHOUT BUILDING RECIRCULATION FOUR HEATERS WITH HORIZONTAL STORAGE TANK WITH OR WITHOUT BUILDING RECIRCULATION INSERT B VACUUM RELIEF VALVE INSTALL...

Страница 42: ...2 Inlet and outlet size 1 1 2 THREE HEATERS Tank Capacity gallons Part Number H W D A 52 9003430205 66 1 4 91 3 4 27 1 4 13 1 4 80 9003430205 70 1 2 95 1 4 31 1 4 9 3 4 120 9003430205 73 1 4 99 1 2 35...

Страница 43: ...he owner is responsible for all other costs Such costs may include but are not limited to a Labor charges for service removal repair or reinstallation of the water heater or any component part b Shipp...

Страница 44: ...44 500 Tennessee Waltz Parkway Ashland City TN 37015 Technical Support 800 527 1953 Parts 800 433 2545 Fax 800 644 9306 www hotwater com...