Instruction manual BFC
59
gis
Confirm with
.
The cursor moves to the minute digits, which flash.
Note
Because the switch-off time can never be earlier
than the switch-on time, the switch-off time setting is
automatically adjusted with the switch-on time.
4. Use and to set the minutes. In the example,
this is
15
.
Confirm with
.
The cursor moves to the switch-off hour digits,
which flash.
11.6.2
Week program: setting the switch-
off time
1. Use and to set the hours. In the example, this
is
12
.
Confirm with
.
The cursor moves to the minute digits, which flash.
2. Use and to set the minutes. In the example,
this is
45
.
Confirm with
.
The cursor moves to the desired water
temperature.
11.6.3
Week program: setting the water
temperature
1. Use and to set the water temperature. In the
example this is 75°C.
Confirm with
.
The cursor moves to
PUMP ON
11.6.4
Week program: setting the program-
controlled pump
1. If required, a pump can be controlled during the
period. Use and to set
PUMP ON
. The pump
ensures a regular circulation of hot water in the hot
water pipes. You can skip this step if you there is
no pump in your hot water circuit.
Confirm with
.
The cursor moves to
SAVE
.
2. Confirm with
.
The display shown in the figure will appear.
3. If you wish, you can use to scroll to another day,
and change more switch-on times
(11.6.1 "Week
program: setting the switch-on time")
and switch-
off times
(11.6.2 "Week program: setting the
switch-off time")
.
4. After changing all desired switch-on and switch off
times, you can start running the week program:
Scroll with to
START OPERATION
.
Confirm with
.
11.7 Adding times to a week program
Call up the menu to
INSERT
switch-on and switch-off
times into a week program as follows:
1.
:
WEEK PROGRAM
|
PROGRAM OVERVIEW
.
Confirm with
.
ON
SU 08»00
OFF
SU 08:00
Tset 65ÉC
PUMP ON
SAVE
ON
SU 08:15
OFF
SU»08:15
Tset 65ÉC
PUMP ON
SAVE
ON
SU 08:15
OFF
SU 12»15
Tset 65ÉC
PUMP ON
SAVE
ON
SU 08:15
OFF
SU 12:45
Tset»65ÉC
PUMP ON
SAVE
ON
SU 08:15
OFF
SU 12:45
Tset 75ÉC
PUMP»ON SAVE
ON
SU 08:15
OFF
SU 12:45
Tset 75ÉC
PUMP»ON SAVE
DAY TIME Tset
ON »SU
08:15 75ÉC P
OFF SU
12:45
ON MO
00:00 65ÉC P
OFF MO
23:59
ON TU
00:00 65ÉC P
OFF TU
23:59
WEEK PROGRAM
START OPERATION
^»PROGRAM OVERVIEW
È
Содержание cyclone BFC - 80
Страница 2: ...www aosmithinternational com your installer...
Страница 4: ...4 Instruction manual BFC gis...
Страница 8: ...Table of contents 8 Instruction manual BFC...
Страница 12: ...Introduction 12 Instruction manual BFC 1 gis...
Страница 27: ...Instruction manual BFC 27 is Types of appliances IMD 0468 R0 C43 C13 C53 B23 C33...
Страница 46: ...Draining 46 Instruction manual BFC 6 gis...
Страница 52: ...Status of the appliance 52 Instruction manual BFC 8 gis...
Страница 56: ...Shutting down 56 Instruction manual BFC 10 gis...
Страница 64: ...Main menu 64 Instruction manual BFC 11 gis The relevant display appears REGULATION INTERVAL 40_80 C...
Страница 82: ...Maintenance frequency 82 Instruction manual BFC 14 is...
Страница 92: ...Appendices 92 Instruction manual BFC 17 is...
Страница 94: ...Instruction manual BFC 94...