background image

8

 

Plumbing connection

Caution:

   

Apply proper sealing to the pipe joints to prevent leakage. At the same time,
the relief valve may not be tightened excessively to avoid damage.

Fig. 5 Water inlet and outlet 

connection diagram 

While installing a control box on the Wall, if the grooves 
or clips are installed on the Wall, lay the control wire into
the grooves or through the clips directly, and then fix the 
control box on a dead plate preinstalled on the wall. In case 
that the gland is embedded in the wall, firstly remove four 
screws of the control box, open the box, and take out the 
control wire from the Control box; plug off the wire from 
the PCB, and then pass the control wire through the 
gland(pay attention to not damage the ten-pin wire); plug 
the ten-pin plug on the PCB, then fix the PCB into the 
backcover, close the front cover, screw down the screws, 
and finally secure the whole control box on the dead plate 
preinstalled on the wall.

ControI Box Connection

 

The power cord and plug has been provided for the water heater. Users only needs to insert the 
plug into the corresponding electrical socket.

Power connection

Caution: 

 Ensure that the socket is grounded reliably. Use an independent high-quality 
socket, its rated current should not be less than 5.5A(CEWHR-PE6-1200)
/13.1A(CEWHR-PE6-3000) and ensure reliable contact with the plug. 

After all the pipes are connected, first open the discharge valve of the water heater, then the 

feed valve. Then fill the water heater with water

, exhaust the air till water stream flows 

uniformly out of the hot water outlet. This indicates that the water heater has been filled up. 
Please close the hot water discharge valve and check all connections for any leakage. If leakage 
occurs, empty the inner tank, repair the leaked connection and then refill the water heater with 
water.For your convenience, please don’t close the feeding valve while filling the water

.

Water filling

Hot Water

(outlet)

Cold Water (inlet)

Handle

Discharge Pipe Joint

Relief Valve

Connect the valve provided with this unit to the inlet 
of the (inlet pipe has a blue cap). The arrow points 
to the direction of water flow (to the water heater). 
The relief valve must be connected to the discharge 
pipe. The hot water pipe is connected to the water 
outlet (outlet pipe has a red cap). If the water pressure 
of the inlet pipe approaches to or exceeds the relief 
limit (0.8 MPa) of the multi-functional relief valve, 
please install a reducing valve on the water inlet pipe 
away from the water heater. Refer to Fig. 5 for pipe 
connection. PPR pipes should be used for connection 
between the tapping pipe in users house and the water heater. 

Discharge Pipe 

Ploor drain 

Mixing water

Front cover   

PCB    

Backcover   

Dead plate  

Junction box  

 Wall

Fig. 6 

Содержание CEWHR-PE6

Страница 1: ...Storage Electrical Water Heater CEWHR PE6 User Guide...

Страница 2: ...as gained respect and support of homeowners contractors architects and specifying engineers in over 60 countries by providing innovative energy saving products designed for years of trouble free servi...

Страница 3: ...ection Tank Anode Protection High Efficiency Energy saving Insulation Installation Instructions 6 Mounting 6 Mounting Procedures and Precautions Mounting Guidelines 7 Pipe Connection 8 Power Connectio...

Страница 4: ...repair the heater In case the water heater is subject to dry heating the generated steam or burning water might lead to serious scald Therefore it is necessary to fill the water heater with water If...

Страница 5: ...fire disaster which would be a threat to life and property security Warning Warning the water heater is not permitted for use without reliable ground wire circuit for power socket In case of the powe...

Страница 6: ...33 0 8 50 40 23 21 CEWHR 40PE6 40 220 50 21 Model Volume Voltage Range Temperature Rated pressure Net weight Hz D S L1 L G1 2 Power Rating Rated Current G1 2 CEWHR 50PE6 CEWHR 80PE6 CEWHR 100PE6 CEWH...

Страница 7: ...e electrical water heater The valve will relieve pressure automatically when piping system pressure exceeds the setting point Discharge pipe is required to connect the valve in a frostless environment...

Страница 8: ...ption set temperature actual temperature timer etc The user can select the set temperature within the range of 35 C 75 C Touch control panel Program Program is to set clock and timers for heating Two...

Страница 9: ...g 50 C please take care The installing surface must be capable of supporting at least four times the weight of the water heater when filled with water If the water heater is not installed on the beari...

Страница 10: ...f 12 mm to drill 2 holes at least 100 mm deep in the wall The two holes should be aligned horizontally The horizontal distance between the 2 holes is shown in the below table Fig 3 The distance A is 5...

Страница 11: ...E6 1200 13 1A CEWHR PE6 3000 and ensure reliable contact with the plug After all the pipes are connected first open the discharge valve of the water heater then the feed valve Then fill the water heat...

Страница 12: ...supply by plug out or power cut heating mode temperature setting timer 1 and standby will load status before the break By power on more than 4 hours the heater could keep clock setting information fo...

Страница 13: ...timers in a day The water heater will work during the period from timer on and timer off 4 Temperature Setting Fig 10 With heater power on user could press Increase button or Decrease button key to s...

Страница 14: ...p operation immediately and contact local authorized dealer for repair to ensure the normal safe and reliable operation of the water heater Safety Valve Safty valve is a kind of protection device agai...

Страница 15: ...from this end the water inlet pipe connection is connected to floor drain by pipes and discharge water from this end 4 Open the water inlet valve to get a maximum tap water flow flush the tank till th...

Страница 16: ...nclosure Drain blocked heater immediately Condensate pipe distorted Check make condensate or not downward facing pipe downwards Call local authorized dealer Display E2 Black wire of two core terminal...

Страница 17: ...Black wire 1200W or 3000W Heating Element Upper side of the tank 800W or 2000W Heating Element Lower side of the tank White wire L N PE Temperature Sensor To Water Tank Yellow Green wire Yellow wire P...

Страница 18: ...A O SMITH WATER HEATER CO LTD A O Smith reserves the right to make product changes or improvements at any time without notice 407920 076 Rev 00...

Отзывы: