Only  professional  installers  acknowledged  by  A.O.SMITH  are  permitted  to  install  the  storage 
electrical  water heater. If the water heater is installed with self-prepared installation materials or by 
un-authorized  personnel,  A.O.SMITH  will  not  be  responsible  for  all  losses  incurred  thereby, 
including but not limited to pipeline leakage, fall or improper installation that may affect normal 
operation and performance of water heater.
The storage electrical water heater is for residential application. Therefore, it may affect life expec-
tation if it is used for commercial application.
After  installation  and  operation  of  the  storage  electrical  water  heater,  users  should  inspect  the 
system regularly and make necessary maintenance according to operation conditions. If any abnor-
mality occurs, please stop operation immediately, and contact local authorized dealer for repair to 
ensure the normal, safe, and reliable operation of the water heater.
The anode rod is a consumable part and it is generally suggested to check and replace the anode rod 
every 2 or 3 years. Users could contact the local authorized dealer for check and replacement to 
extend life expectation of water heater.
Prior  to  any  maintenance  or  repair  of  the  storage  electrical  water  heater,  please  cut  off  power 
supply. Unauthorized personnel are not permitted to adjust and repair the heater.
In case the water heater is subject to dry heating, the generated steam or burning water might lead
 to serious scald. Therefore, it is necessary to fill the water heater with water. If dry heating 
occurs, cut off the power and water supply at once, stop the operation,contact local authorized 
dealer

.

and carry out inspection or repair by our company recommended professional installers.    

In case of any component soaked by water, the water heater is not permitted to use until checked by 
authorized service staff.
Main components of the storage electrical heater are protected by insulation material to ensure 
safety use. Any damaged power cords should be replaced by authorized service staff.
The pressure relief valve, equipped on the storage electrical water heater, is forbidden to change 
installation position or be blocked. Discharge pipe is required to connect the valve and down toward 
floor drain.
In case of any fault of phase line and  neutral line

 

,the power-off protection system will cut off the 

connection between water heater and electric supply circuit instantaneously. Please stop using, pull 
the plug, and contact local authorized dealer

.

This is only suitable for the model with the power-off protection system.

 

Water, including hot water, out of the storage electrical water heater is not permitted for drinking.
Electricity  for  the  storage  electrical  water  heater  should  be  supplied  by  independent  branch  of 
circuit, of which electricity meter, breaker, maximum current need to be checked by professional 
electrician in advance.

Содержание CEWHR-PE6

Страница 1: ...Storage Electrical Water Heater CEWHR PE6 User Guide...

Страница 2: ...as gained respect and support of homeowners contractors architects and specifying engineers in over 60 countries by providing innovative energy saving products designed for years of trouble free servi...

Страница 3: ...ection Tank Anode Protection High Efficiency Energy saving Insulation Installation Instructions 6 Mounting 6 Mounting Procedures and Precautions Mounting Guidelines 7 Pipe Connection 8 Power Connectio...

Страница 4: ...repair the heater In case the water heater is subject to dry heating the generated steam or burning water might lead to serious scald Therefore it is necessary to fill the water heater with water If...

Страница 5: ...fire disaster which would be a threat to life and property security Warning Warning the water heater is not permitted for use without reliable ground wire circuit for power socket In case of the powe...

Страница 6: ...33 0 8 50 40 23 21 CEWHR 40PE6 40 220 50 21 Model Volume Voltage Range Temperature Rated pressure Net weight Hz D S L1 L G1 2 Power Rating Rated Current G1 2 CEWHR 50PE6 CEWHR 80PE6 CEWHR 100PE6 CEWH...

Страница 7: ...e electrical water heater The valve will relieve pressure automatically when piping system pressure exceeds the setting point Discharge pipe is required to connect the valve in a frostless environment...

Страница 8: ...ption set temperature actual temperature timer etc The user can select the set temperature within the range of 35 C 75 C Touch control panel Program Program is to set clock and timers for heating Two...

Страница 9: ...g 50 C please take care The installing surface must be capable of supporting at least four times the weight of the water heater when filled with water If the water heater is not installed on the beari...

Страница 10: ...f 12 mm to drill 2 holes at least 100 mm deep in the wall The two holes should be aligned horizontally The horizontal distance between the 2 holes is shown in the below table Fig 3 The distance A is 5...

Страница 11: ...E6 1200 13 1A CEWHR PE6 3000 and ensure reliable contact with the plug After all the pipes are connected first open the discharge valve of the water heater then the feed valve Then fill the water heat...

Страница 12: ...supply by plug out or power cut heating mode temperature setting timer 1 and standby will load status before the break By power on more than 4 hours the heater could keep clock setting information fo...

Страница 13: ...timers in a day The water heater will work during the period from timer on and timer off 4 Temperature Setting Fig 10 With heater power on user could press Increase button or Decrease button key to s...

Страница 14: ...p operation immediately and contact local authorized dealer for repair to ensure the normal safe and reliable operation of the water heater Safety Valve Safty valve is a kind of protection device agai...

Страница 15: ...from this end the water inlet pipe connection is connected to floor drain by pipes and discharge water from this end 4 Open the water inlet valve to get a maximum tap water flow flush the tank till th...

Страница 16: ...nclosure Drain blocked heater immediately Condensate pipe distorted Check make condensate or not downward facing pipe downwards Call local authorized dealer Display E2 Black wire of two core terminal...

Страница 17: ...Black wire 1200W or 3000W Heating Element Upper side of the tank 800W or 2000W Heating Element Lower side of the tank White wire L N PE Temperature Sensor To Water Tank Yellow Green wire Yellow wire P...

Страница 18: ...A O SMITH WATER HEATER CO LTD A O Smith reserves the right to make product changes or improvements at any time without notice 407920 076 Rev 00...