9
Operation Instructions
Increase button
Caution:
.
1. Initial power
For the first-ever power connection, electronic controller will run self-inspection program. All screen
indicators will glow (Fig. 7) and go out seconds later indicating the heater is standby.
2. Power
ON/OFF
(Fig.8)
Press the ON/OFF key " ", the water heater is on. Firstly, the electronic controller default state is at
preset temperature mode and default display time. Display the current clock " 12:00 ".The setting
temperature is 70
℃.
Touch control panel functions
MODE
PROGRAM
INSTANT
SINGLE
STANDARD
MULTIPLE
1
2
Decrease buttonPower On/Off
Fig. 7
Notice:
When water heater is disconnected with power supply by plug-out or power cut, heating mode
、
temperature setting
、
timer-1 and standby will load status before the break.By power-on more than 4
hours, the heater could keep clock setting information for 72 hours when power supply is cut-off.
3. Clock Setting
(Fig.9)
In non-timing mode, press the "PROGRAM" key for 3 seconds approximately and the hour digit
flashes. Press the "Increase button" or "Decrease button" key to set the hour; then, press "PROGRAM"
key again, the minute digit starts flashing and then press the "Increase button" or "Decrease button"
key to set the minute. In case of pressing continuously, the data changes ceaselessly; then press
"PROGRAM" key again and exit the clock setting mode.
Fig. 8
Fig. 9
Fig. 10
Before using the water heater , make sure that it should be filled with water and
the power plug has been connected properly
Operation instruction