Indication
Cause
Measure
Insufficient or no hot
water - Pilot flame is on
Temperature set too low.
Turn the temperature control knob to a
higher position.
Thermocouple is broken.
Replace thermocouple.
Control knob is in position
[ ] (pilot flame is on).
Turn the temperature control knob to the
desired position (preferably position 4). The
water heater now functions fully automatic.
Hot water storage is
empty.
Reduce hot water usage so the water heater
has enough time to heat the water.
Condensation of flue
gases.
See Condensation.
Cause cannot be
determined.
Turn the operation control knob to [ ], close
the gas supply valve and contact your
installer.
Water leakage
There is a leakage from a
threaded water
connection.
Tighten the threaded connection.
There is a condensate
leakage.
Reduce hot water usage so the water heater
has enough time to heat the water.
There is a leakage from
another nearby water
heater or pipe segment.
Trace the leakage.
.
12 Appendices
12.1 Technical details
Description
Unit
BTL 85
BTL 100
Capacity
l
268
358
Empty Weight
kg
124
151
Maximum floor load
kg
392
509
Maximum operating pressure
kPa (bar)
550 (5.5)
550 (5.5)
Control thermostat - adjustment
range
°C
40-80
40-80
Control thermostat -
factory setting
°C
30
30
0313126_BTL_UKUK_V1.1, 30-11-2018
23
Number of anodes
-
1
1
Heating time ΔT = 45 °C
min.
35
47