background image

8.2.5 Placement of the water
heater

Before you install the water connections and gas

 

connections, place the water heater on the

 

correct position and make sure that the water

 

heater is level.

C

B

D

9

10

4

14

14

14

6

5

4

3

11

IMD-1331 R0

16

A

4

1

5

15

12

T

1. Pressure reducing valve
(mandatory if the mains water pressure is too high)
3. T&P valve (optional)
4. Stop valve (recommended)
5. Non-return valve
6. Circulation pump (optional)
9. Drain valve
10. Manual gas valve
11. Service stop valve
12. Temperature gauge (optional)
14. Draw-off point
15. Expansion valve
16. Expansion vessel

A. Cold water supply
B. Hot water outlet
C. Circulation pipe (optional)
D. Gas supply

Use this installation diagram when
you:
-

install the water connections
(see 8.4)

-

install the gas connection (see
8.5)

-

fill the water heater (see
8.7.1)

-

drain the water heater (see
8.8)

8.4 Water connections

8.4.1 Cold water connection

Install the cold water connection:
1. Install an approved stop valve (4), as

required by the applicable regulations (see
6).

2. Install an approved pressure reducing valve

(1) to prevent that the pressure in the cold
water supply pipe exceeds the maximum
working pressure of the tank, 8 bar. Refer to
the Technical details.

3. Install a non-return valve (5).
4. Install an expansion valve (15).
5. Connect the overflow connection of the

expansion valve, to an open waste water
pipe.

6. Install an expansion vessel (16).

8.4.2 Hot water connection

Note
Insulate long hot water pipes to prevent
unnecessary energy loss.

Install the hot water connection:
1. Install a stop valve (11) in the hot water

outlet pipe for service reasons.

2. If applicable, install a temperature gauge

(12).

3. Install a T&P valve (3).

8.4.3 Circulation connection

Install a circulation system when an immediate
flow of hot water at draw-off points is required.
This improves comfort and reduces water
wastage.

n

14

Installation, Maintenance and Service part

8.3 Installation diagram

Fig. Installation diagram

Warning

This appliance 

must

 be installed on a 

non-

flammable

 floor or surface.

w

Содержание BTL 100

Страница 1: ...Innovation has a name BTL 85 BTL 100 0313126 4918 Reserved Changes United Kingdom Ireland HOT WATER STORAGE HEATERS Installation User and Service Manual...

Страница 2: ......

Страница 3: ...Supplier The BTL water heater is designed in accordance with the applicable regulations The water heater is delivered with the CE marking and all necessary documentation to obey these regulations A O...

Страница 4: ...ons in this manual n Caution Read this manual carefully before you start the water heater It can cause personal injury and damage to the water heater when you do not read the manual and or do not obey...

Страница 5: ...perature setting 9 4 2 Turn off the water heater 9 4 2 1 Turn off for a short period 9 4 2 2 Turn off for a long period 9 Installation Maintenance and Service part 9 5 Introduction 9 5 1 About the wat...

Страница 6: ...er for sanitary purposes Cold water enters the tank 3 through the water inlet 2 The heated water leaves the tank at the top through the hot water outlet 1 When hot water is used the tank of the water...

Страница 7: ...g or has explained how the water heater should be used these persons can use the water heater Caution This water heater is not intended to be used by children Always supervise children and make sure t...

Страница 8: ...in the system freezes the frost protection is activated when the water heater is in OFF mode The frost protection starts when the temperature of the water drops below 5 C The water heater will heat th...

Страница 9: ...water heater needs to be turned off for more than 2 months contact your service and maintenance engineer to decommission the water heater 5 Introduction 5 1 About the water heater The BTL water heate...

Страница 10: ...ssure and the burner pressure are correct If the gas supply pressure is not correct contact your mains gas supply company Do not use the water heater Danger Never deactivate the T R S Backdraft of flu...

Страница 11: ...the cold water main supply Pressure reducing valve The pressure reducing valve reduces the water mains pressure if necessary T P valve Temperature and pressure relief valve 1 The T P valve is a temper...

Страница 12: ...control valve The gas control valve controls the gas supply to the burners Fig Components water heater 8 6 7 6 1 9 10 11 12 13 14 16 15 2 4 3 5 1 Draught diverter 2 T R S sensor 3 T R S thermostat 4 T...

Страница 13: ...e If necessary adjust the installation site to keep it frost free Air humidity and ambient temperature Air humidity Max 93 RH at 25 C Ambient temperature Functionality 0 T 40 C 8 2 2 Maximum floor loa...

Страница 14: ...connection 1 Install an approved stop valve 4 as required by the applicable regulations see 6 2 Install an approved pressure reducing valve 1 to prevent that the pressure in the cold water supply pipe...

Страница 15: ...manual gas valve on a spot accessible for the user Install the gas connection 1 Install the manual gas valve 10 in the gas supply pipe 2 Make sure that the gas pipe is clean before use If necessary re...

Страница 16: ...of the pressure relief valve of the inlet security group 2 or the T P valve 3 If water comes out Examine if the water supply pressure is greater than the specified value in the Technical details If ne...

Страница 17: ...eed from the supplier of your water heater The conversion kit contains all the parts needed to do the conversion and an instruction how to do the conversion The following conversions are possible Conv...

Страница 18: ...the anode The life cycle of the anode is determined by the quality and the quantity of the water that flows through the water heater Inspect the anode at least once a year to make sure that the tank i...

Страница 19: ...nk 11 Put the isolating material in place 12 Put the cover plate in place and tighten the two screws 13 Fill the water heater Fig Cleaning opening 10 3 Gas side maintenance Do gas side maintenance whe...

Страница 20: ...pply pressure is not correct contact your mains gas supply company Do not use the water heater 3 Make sure that the burner pressure is correct refer to burner pressure see 8 7 2 4 Turn on the water he...

Страница 21: ...n 11 1 3 Condensation Condensation of flue gases can occur on the cold surfaces of the combustion chamber and the flue gas discharge pipe when the water heater is filled with cold water or when the w...

Страница 22: ...water heater see 4 1 Control knob is in position Turn on the water heater see 4 1 Thermocouple is not working Replace thermocouple Thermocouple does not make contact Restore contact Turn on the water...

Страница 23: ...the operation control knob to close the gas supply valve and contact your installer Water leakage There is a leakage from a threaded water connection Tighten the threaded connection There is a condens...

Страница 24: ...let mm 130 130 Dimensions connections 1 Cold water supply connection female 1 1 1 4 2 Hot water outlet connection female 1 1 1 4 3 Gas control valve connection male Rp 1 2 Rp 1 2 4 Drain valve connect...

Страница 25: ...ergy label B C Energy efficiency 58 58 Daily electricity usage kWh 0 0 Daily fuel consumption kWh GCV 37 940 42 545 Mixed water 40 C V40 l 1246 648 Additional load profile Load profile XXL 3XL Energy...

Страница 26: ...Description Unit BTL 85 BTL 100 Daily fuel consumption kWh GCV 44 315 72 544 Mixed water 40 C V40 l 538 649 26 Installation Maintenance and Service part...

Страница 27: ...rate flue gases nominal load kg h 74 72 Flue gas temperature nominal load C 142 125 Gas category 3 G30 Diameter main orifice mm 1 45 1 45 Diameter orifice pilot burner mm 2 x 0 16 2 x 0 16 Nominal lo...

Страница 28: ...Gross kW 17 9 17 8 Nominal output kW 13 9 14 4 Supply pressure mbar 37 0 37 0 Burner pressure mbar Gas consumption kg h 1 3 1 3 NOx emission mg kWh GCV 9 9 Mass flow rate flue gases nominal load kg h...

Страница 29: ...12 5 Declaration of conformity 0313126_BTL_UKUK_V1 1 30 11 2018 29...

Страница 30: ...l times can freely circulate a separately installed heat exchanger is mandatory for heating saline water or corrosive water The tank is safeguarded against harmful scaling and lime build up by means o...

Страница 31: ...sed dealer for A O Smith Water Products Company products Inspection of the water heater as referred to in Articles 1 and 2 shall take place in one of the laboratories of A O Smith Water Products Compa...

Страница 32: ...h 1800 Bourges 01 3975 5140 ou 008008 AOSMITH 2676484 info aosmith nl www aosmith fr United Kingdom A O Smith Water Heaters Unit B8 Armstrong Mall Southwood Business Park Farnborough Hampshire GU14 0N...